XRF-Spectrometer LXRF-A10

XRF-Spectrometer LXRF-A10 is a microprocessor controlled high-count throughput unit with low detection limits for wide range of elements. Provision of multi-elemental analysis with detection limits upto 1 ppm. Built-in movable platform for easy location of testing point.High resolution detector improves analysis accuracy. Equipped with safety features of optical tube shielding with no X-ray radiation and high voltage emergency locking.

Buy Now View Catalog
Measureable elements S to U
Detection limit 1 ppm
Temperature 15 ~ 30 °C
Elemental content 1 ppm to 99 %
Repeatability 0.001
Stability 0.001
Power supply AC 220 V ± 5 V
Dimensions 550 x 410 x 320 mm
Weight 45 kg
  • Detection limit – 1 ppm
    Measureable elements – S to U
    Elemental content – 1 ppm to 99 %
    Movable sample platform for easy detection of testing point
    Built-in electric cooling Si-PIN detector
    Safety features - optical tube shielding with no X-ray radiation and high voltage emergency locking

Used in detection of plating thickness of metals, concentration of plating solution , RoHS detection and analysis, full-element analysis and electro plating industries

{"Measureable elements":"S to U","Detection limit":"1 ppm","Temperature":"15 ~ 30 \u00b0C","Elemental content":"1 ppm to 99 %","Repeatability":"0.001","Stability":"0.001","Power supply":"AC 220 V \u00b1 5 V","Dimensions":"550 x 410 x 320 mm","Weight":"45 kg"}
Detection limit – 1 ppm
Measureable elements – S to U
Elemental content – 1 ppm to 99 %
Movable sample platform for easy detection of testing point
Built-in electric cooling Si-PIN detector
Safety features - optical tube shielding with no X-ray radiation and high voltage emergency locking
Used in detection of plating thickness of metals, concentration of plating solution , RoHS detection and analysis, full-element analysis and electro plating industries


Related Products of XRF Spectrometer

Handheld XRF Spectrometer LXRF-B10

Handheld XRF Spectrometer LXRF-B10

Analytical Method : Energy dispersive X-ray fluorescence analytical Method

Elements Measuring : Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured

Range : Simultaneous detector

Handheld XRF Spectrometer LXRF-B11

Handheld XRF Spectrometer LXRF-B11

Analytical Method : Energy dispersive X-ray fluorescence analytical Method

Elements Measuring : Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured

Range : Simultaneous detector

Atomic Fluorescence Spectrometer

Atomic Fluorescence Spectrometer LAFS-A10

Beam Configuration Dual Channel
Elements ( Measuring Range )
As, Se, Pb, Bi, Sb, Te, Sn < 0.01 µg/L
Hg, Cd < 0.001 µg/L
Zn < 1.0 µg/L
Ge < 0.1 µg/L
Precision ( RSD ) < 1.0

XRD Diffractometer

XRD Diffractometer LXRD-A10

X-ray Tuble Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW
Focus Size 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm
Stability ≤ 0.01 %

ICP Spectrometer

ICP spectrometer LICP-A10
Wavelength range ( 3600 lines / mm ) 180 to 500 nm
Wavelength range ( 2400 lines / mm ) 180 to 800 nm
Temperature 20 ~ 28 °C
ICP Spectrometer LICP-B10
Monochromator Specifications
Optical type Czerny turner
Resolution ≤ 0.015nm (3600 line grating)
≤ 0.030nm (2400 line grating)
Focal length 1000 mm
Grating specifications huge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling area
Wavelength range 195 to 500 nm for 3600 line grating
195 to 800 nm for 2400 line grating
Solid State Power Specifications
Frequency 27.12 MHz
Frequency stability: < 0.05%
Spray chamber Scott double pass spray chamber
Output power 800 W to 1600 W, adjustable with power efficiency more than 65%
Output power stability ≤ 0.05%
Induction coil 25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)
Technical Specifications
Suitable sample content range Liquid sample: 0.01 ppm to several thousand ppm
Solid or power sample: 0.001% to 70%
Repeatability short-term stability- RSD ≤ 1.5%
Long-term stability: RSD ≤ 2%
Test speed 5 to 8 elements / min
Limits of detection (LOD, µg/L) for most elements 1ppb to 10ppb

FTIR Spectrometer

FTIR Spectrometer LIR-B10

Spectral Range 7800 cm-1 to 350 cm-1
Resolution 0.85 cm-1
Wave number precision ± 0.01 cm-1

Angular Spectrometer

Angular Spectrometer LASM-A10

Angle Measurement Accuracy 1inch
Optical Parameter
Focal Length 170 mm
Effective Aperture Φ 22 mm
Field of View 3° 22inch
Focal Length of Telescope’s Eyepiece 24.3 mm
Maximum Length Between Collimator and Telescope 120 mm
Slit Width 0.02 to 2 mm
Diopter Compensation Range ≥ ± 5 diopters
Divided Circle
Diameter Φ178 mm
Circle Graduation 0° to 360°
Division 0.5°
Vernier Reading Value 1inch