Double Beam UV-Vis Spectrophotometer LUS-B11

Double Beam UV-Vis Spectrophotometer LUS-B11 is a compact, tabletop, wide screen double beam spectrophotometer comprising double beam long light path design, offers 190 to 1100 nm of wavelength range with 1200 L/mm grating. Features automatic calibration of all baseline, wavelength, and dark current, it has rigid 16 mm dicast aluminium base as optical mount. Equipped with 6 inches LCD display, standard software and USB interface, this spectrometer provides direct operation to multi functions and display the test results curve and data. With unique 520 mm long light path, it ensures great resolution with stability and reliability.

Buy Now View Catalog
Wavelength range 190 to 1100 nm
Spectral bandwidth 1.8 nm
Optical system Double beam; 1200 lines/mm grating
Wavelength accuracy ±0.1nm (D2 656.1nm), ±0.3nm @ all
Wavelength repeatability 0.2 nm
Photometric range -0.3 to 3 A; 0 to 200% T; 0 to 9999 C
Photometric accuracy ±0.2% T (0 to 100% T)
Photometric repeatability ≤0.1% T (0 to 100% T)
Noise ± 0.0005 A/h
Light source Tungsten lamp, Deuterium lamp
Stray light ≤0.03% T @ 220 nm,360 nm
Stability ± 0.001 A/h @ 500nm
Display 320×240 Dots (6 inches) LCD display
Baseline Flatness ±0.001A/h
Detector Silicon photodiode
Function Spectrum scanning, Standard curve, Kinetics, Multi wavelength scanning, DNA/Protein testing
Interface USB
Printer Parallel port
PC software Yes
Power supply AC 220 V/110 V,50/60 Hz
Dimensions (W×D×H) 625×430×206 mm
Weight 30 kg
  • Wide screen double beam spectrophotometer
    Unique double beam 520 mm long light path design
    190 to 1100 nm of wavelength range with 1200 L/mm grating
    Automatic calibration of all baseline, wavelength, and dark current
    Rigid 16 mm dicast aluminium base as optical mount
    6 inches LCD display, standard software and USB interface
    Direct operation to multi functions: spectrum scanning, standard curve, kinetics, multi wavelength scanning, DNA/Protein testing
    Tungsten and deuterium lamp as light source
    Great resolution with stability and reliability

Double Beam UV-Visible Spectrophotometer are used for analysis of band gap, optical coatings and thin films, quantitative analyses, kinetics, wavelength scanning, and DNA and Protein analysis across clinical and research laboratories.

{"Wavelength range":"190 to 1100 nm","Spectral bandwidth":"1.8 nm","Optical system":"Double beam; 1200 lines\/mm grating","Wavelength accuracy":"\u00b10.1nm (D2 656.1nm), \u00b10.3nm @ all","Wavelength repeatability":"0.2 nm","Photometric range":"-0.3 to 3 A; 0 to 200% T; 0 to 9999 C","Photometric accuracy":"\u00b10.2% T (0 to 100% T)","Photometric repeatability":"\u22640.1% T (0 to 100% T)","Noise":"\u00b1 0.0005 A\/h","Light source":"Tungsten lamp, Deuterium lamp","Stray light":"\u22640.03% T @ 220 nm,360 nm","Stability":"\u00b1 0.001 A\/h @ 500nm","Display":"320\u00d7240 Dots (6 inches) LCD display","Baseline Flatness":"\u00b10.001A\/h","Detector":"Silicon photodiode","Function":"Spectrum scanning, Standard curve, Kinetics, Multi wavelength scanning, DNA\/Protein testing","Interface":"USB","Printer":"Parallel port","PC software":"Yes","Power supply":"AC 220 V\/110 V\uff0c50\/60 Hz","Dimensions (W\u00d7D\u00d7H)":"625\u00d7430\u00d7206 mm","Weight":"30 kg"}
Wide screen double beam spectrophotometer
Unique double beam 520 mm long light path design
190 to 1100 nm of wavelength range with 1200 L/mm grating
Automatic calibration of all baseline, wavelength, and dark current
Rigid 16 mm dicast aluminium base as optical mount
6 inches LCD display, standard software and USB interface
Direct operation to multi functions: spectrum scanning, standard curve, kinetics, multi wavelength scanning, DNA/Protein testing
Tungsten and deuterium lamp as light source
Great resolution with stability and reliability
Double Beam UV-Visible Spectrophotometer are used for analysis of band gap, optical coatings and thin films, quantitative analyses, kinetics, wavelength scanning, and DNA and Protein analysis across clinical and research laboratories.


Related Products of Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV-Vis Spectrophotometer LUS-B10

Double Beam UV-Vis Spectrophotometer LUS-B10

Wavelength Range : 190 to 1100 nm

Spectral Bandwidth : 1.8 nm

Optical System : Double beam

Double Beam UV-Vis Spectrophotometer LUS-B13

Double Beam UV-Vis Spectrophotometer LUS-B13

Wavelength Range : 190 to 1100 nm

Spectral Bandwidth : 1.0 nm

Optical System : Double beam

Double Beam UV-Vis Spectrophotometer LUS-B12
Double Beam UV-Vis Spectrophotometer LUS-B12

Wavelength Range : 190 to 1100 nm

Spectral Bandwidth : 1.8 nm

Optical System : Double beam, C-T monochromator,1200 L/mm holographic grating

Double Beam UV-Vis Spectrophotometer LUS-B40
Double Beam UV-Vis Spectrophotometer LUS-B40

Wavelength range : 190 to 1100 nm

Spectral bandwidth : 0.5/1/2/4 nm

Wavelength Accuracy : ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range

Double Beam UV/Vis Spectrophotometer LUS-B31

Double Beam UV/Vis Spectrophotometer LUS-B31

Wavelength range : 190 to 1100 nm

Spectral bandwidth : 1 nm

Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Double Beam UV/Vis Spectrophotometer LUS-B16

Double Beam UV/Vis Spectrophotometer LUS-B16

Wavelength Range : 190 ~ 1100 nm

Setting Wavelength : Automatic

Spectral Bandwidth : 0.5 / 1.0 / 2.0 / 4.0 nm adjustable

Double beam UV-Visible Spectrophotometer LUS-B15
Double beam UV-Visible Spectrophotometer LUS-B15

Wavelength range : 190 ~ 1100 nm

Spectral bandwidth : 2 nm

Wavelength accuracy : 0.5 nm

Double Beam UV/Vis Spectrophotometer LUS-B32
Double Beam UV/Vis Spectrophotometer LUS-B32

Wavelength range : 190 to 1100 nm

Spectral bandwidth : 0.5/1/2/4/5 nm

Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer LAAS-A11

Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy ≤ ± 0.5 nm

Atomic Absorption Spectrophotometer LAAS-A13

Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-A21
Wavelength range 200 - 850 nm
Path length 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy ± 1 nm
Nano Spectrophotometer LNS-A10
Wavelength range 200 - 800 nm
Path length 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy ± 1 nm

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer LFS-A12

Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm

Fluorescence Spectrophotometer LFS-A10

Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm

Portable Spectrophotometer

Portable Spectrophotometer LSP-A31
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Portable Spectrophotometer LSP-A30
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode

NIR Spectrophotometer

NIR Spectrophotometer LNIR-A10

Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05

Talk to us?