Double Beam UV-Vis Spectrophotometer LUS-B40

Double Beam UV-Vis Spectrophotometer LUS-B40 a bench top device with 190 nm to 1100 nm wavelength range, and offers spectral bandwidth of 0.5/1/2/4 nm. Equipped with 16 mm thick rigid aluminium board as optical base, which highly ensures stability and reliability. Features dual optical path, dual beam optical system, dual detector, uses high performance imported prism grating, Tungsten Lamp & Deuterium Lamp as light source, and Imported silicon photodiode as detector with stronger stability, reliability, delivers results that are more accurate. Designed with 10 inch TFT Touch colored screen, can work on powerful software as well, and it performs functions like Photometric measurement, Quantitative measurement, Kinetics, Spectrum scan, DNA/Protein test, Multi-wavelength test etc. Three operation modes are available; they are Host, Computer and Mobile phone (App). This advance, high quality spectrophotometer supports USB data transfer and storage system.

Buy Now View Catalog
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4 nm
Wavelength Accuracy ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range
Wavelength Repeatability ≤ 0.1 nm
Optical system Double beam grating 1200 lines/mm
Photometric Range 0 to 200 %T, -0.3 to 3.0 A, 0 to 9999 C (0 to 9999F)
Photometric Accuracy
± 0.2T (0 to 1009 % T)
± 0.002 Abs (0 to 0.5 Abs)
± 0.004 Abs (0.5 to1.0 Abs)
Photometric Repeatability
≤ 0.05 % 6T (0 to100 % 6T)
0.001 Abs (0 to 0.5 Abs)
0.002 Abs (0.5 to 1.0 Abs)
Detector Imported silicon photodiode
Light source Imported Deuterium and Tungsten lamp
Stray light ≤ 0.03 % T @ 220 nm, 360 nm
Stability ± 0.0004 A/h @ 500 nm
Data Output Port USB drive, USB host, RS232
Print Port USB drive, USB host, RS232
Power supply AC 220 V, 50 Hz or 110 V, 60 Hz
Noise ± 0.0004
Baseline flatness ± 0.001 A
Work mode T, A, C, E
Scanning speed Hi, Med, Low (Max. 3000 nm/min)
Wavelength setting Auto
Cuvette holder 10 mm single hole cell holder
Display 10.1 inches TFT colored capacitive touch screen
Dimension 630 × 430 × 210 mm
Gross weight 28 kg
  • 10 inch touch screen with built-in 32G memory
    Equipped with 16 mm thick rigid aluminium board as optical base
    Tungsten Lamp & Deuterium Lamp as light source, and Imported silicon photodiode as detector
    Automatic 5 position cell holder with long light path
    Automatic 10 mm, 8 position cell holder
    Powerful storage function, Supports Bluetooth connectivity function, 3D graphs
    21CFR PART 11 requirements compatible PC software
    Can print data and graphs directly by A4 printer
    Supports USB data transfer and storage system
    Two types of automatic cell holders (optional)
    Installation of Integrating sphere (optional)
Cuvettes
Power cord
8 Cells, 10 mm Auto Cuvette Holder
Glass Cuvette
Quartz Cuvette

Double beam UV-Vis spectrophotometer features flexible spectral bandwidth, dual beam steady optics and exceptional accuracy for photometric concentration, multi-wavelength, spectrum scanning, kinetics, quantitation, DNA, RNA and protein analysis across biochemistry, medical science, pharmacy, biotechnology, food science, environmental science, etc.

{"Wavelength range":"190 to 1100 nm","Spectral bandwidth":"0.5\/1\/2\/4 nm","Wavelength Accuracy":"\u00b1 0.1nm (D2, 656.1 nm), \u00b1 0.3 nm full range","Wavelength Repeatability":"\u2264 0.1 nm","Optical system":"Double beam grating 1200 lines\/mm","Photometric Range":"0 to 200 %T, -0.3 to 3.0 A, 0 to 9999 C (0 to 9999F)","Photometric Accuracy":"\n \n \n \n
\u00b1 0.2T (0 to 1009 % T)<\/td>\n <\/tr>\n
\u00b1 0.002 Abs (0 to 0.5 Abs)<\/td>\n <\/tr>\n
\u00b1 0.004 Abs (0.5 to1.0 Abs\uff09<\/td>\n <\/tr>\n <\/table>","Photometric Repeatability":"\n \n \n \n
\u2264 0.05 % 6T (0 to100 % 6T)<\/td>\n <\/tr>\n
0.001 Abs (0 to 0.5 Abs)<\/td>\n <\/tr>\n
0.002 Abs (0.5 to 1.0 Abs)<\/td>\n <\/tr>\n <\/table>","Detector":"Imported silicon photodiode","Light source":"Imported Deuterium and Tungsten lamp","Stray light":"\u2264 0.03 % T @ 220 nm, 360 nm","Stability":"\u00b1 0.0004 A\/h @ 500 nm","Data Output Port":"USB drive, USB host, RS232","Print Port":"USB drive, USB host, RS232","Power supply":"AC 220 V, 50 Hz or 110 V, 60 Hz","Noise":"\u00b1 0.0004","Baseline flatness":"\u00b1 0.001 A","Work mode":"T, A, C, E","Scanning speed":"Hi, Med, Low (Max. 3000 nm\/min)","Wavelength setting":"Auto","Cuvette holder":"10 mm single hole cell holder","Display":"10.1 inches TFT colored capacitive touch screen","Dimension":"630 \u00d7 430 \u00d7 210 mm","Gross weight":"28 kg"}
10 inch touch screen with built-in 32G memory
Equipped with 16 mm thick rigid aluminium board as optical base
Tungsten Lamp & Deuterium Lamp as light source, and Imported silicon photodiode as detector
Automatic 5 position cell holder with long light path
Automatic 10 mm, 8 position cell holder
Powerful storage function, Supports Bluetooth connectivity function, 3D graphs
21CFR PART 11 requirements compatible PC software
Can print data and graphs directly by A4 printer
Supports USB data transfer and storage system
Two types of automatic cell holders (optional)
Installation of Integrating sphere (optional)
Double beam UV-Vis spectrophotometer features flexible spectral bandwidth, dual beam steady optics and exceptional accuracy for photometric concentration, multi-wavelength, spectrum scanning, kinetics, quantitation, DNA, RNA and protein analysis across biochemistry, medical science, pharmacy, biotechnology, food science, environmental science, etc.


Related Products of Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer LUS-B16

Double Beam UV/Vis Spectrophotometer LUS-B16

Wavelength Range : 190 ~ 1100 nm

Setting Wavelength : Automatic

Spectral Bandwidth : 0.5 / 1.0 / 2.0 / 4.0 nm adjustable

Double Beam UV/Vis Spectrophotometer LUS-B31

Double Beam UV/Vis Spectrophotometer LUS-B31

Wavelength range : 190 to 1100 nm

Spectral bandwidth : 1 nm

Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Double Beam UV-Vis Spectrophotometer LUS-B20
Double Beam UV-Vis Spectrophotometer LUS-B20

Wavelength range : 190 to 1100 nm

Spectral bandwidth : 1.0 to 5.0 nm (adjustable)

Optical system : Double beam, C-T monochromator, 1600 L/mm holographic grating

Double Beam UV-Vis Spectrophotometer LUS-B12
Double Beam UV-Vis Spectrophotometer LUS-B12

Wavelength Range : 190 to 1100 nm

Spectral Bandwidth : 1.8 nm

Optical System : Double beam, C-T monochromator,1200 L/mm holographic grating

Double Beam UV/Vis Spectrophotometer LUS-B32

Double Beam UV/Vis Spectrophotometer LUS-B32

Wavelength range : 190 to 1100 nm

Spectral bandwidth : 0.5/1/2/4/5 nm

Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Double Beam UV-Vis Spectrophotometer LUS-B13

Double Beam UV-Vis Spectrophotometer LUS-B13

Wavelength Range : 190 to 1100 nm

Spectral Bandwidth : 1.0 nm

Optical System : Double beam

Double beam UV-Visible Spectrophotometer LUS-B15
Double beam UV-Visible Spectrophotometer LUS-B15

Wavelength range : 190 ~ 1100 nm

Spectral bandwidth : 2 nm

Wavelength accuracy : 0.5 nm

Double Beam UV-Vis Spectrophotometer LUS-B11
Double Beam UV-Vis Spectrophotometer LUS-B11

Wavelength range : 190 to 1100 nm

Spectral bandwidth : 1.8 nm

Optical system : Double beam; 1200 lines/mm grating

NIR Spectrophotometer LNIR-A10

Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05

Portable Spectrophotometer LSP-A31

Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Portable Spectrophotometer LSP-A30
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer LAAS-A13
Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm

Atomic Absorption Spectrophotometer LAAS-A11

Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy ≤ ± 0.5 nm

Fluorescence Spectrophotometer LFS-A10

Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Fluorescence Spectrophotometer LFS-A12
Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-A21
Wavelength range 200 - 850 nm
Path length 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy ± 1 nm

Nano Spectrophotometer LNS-A10

Wavelength range 200 - 800 nm
Path length 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy ± 1 nm

Talk to us?