Double Beam UV-Vis Spectrophotometer LUS-B13 is a compact, tabletop double beam designed UV-Vis spectrophotometer comprising Silicon photodiode detector, Tungsten and Deuterium lamp as light source. Equipped with wide wavelength range of 190 nm to 1100 nm, it offers 1.0 nm of bandwidth with automatic setting of wavelength. Designed with 6 inches LCD display, import source and receiver system, it provides rich measurement methods with high performance and reliability.

Buy Now View Catalog
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1.0 nm
Optical System Double beam
Wavelength Accuracy ±0.3 nm
Wavelength Repeatability ≤0.1 nm
Wavelength Resolution 0.1 nm
Photometric Display Range -4 to 4 A
Photometric Mode T, A, C, E
Photometric Accuracy ±0.3% τ (0 to 100%τ) ± 0.002 A (0 to 0.5 A) ± 0.003 A (0.5 A to 1 A)
Photometric Repeatability 0.15% τ (0 to 100% τ) ± 0.001 A (0 to 0.5 A) ± 0.0015 A (0.5 A to 1 A)
Light Source Tungsten lamp, Deuterium lamp
Stray Light ≤0.03% τ (220 nm NaI, 340 nm NaNO2)
Stability 0.0005 A/h @500 nm
Noise ± 0.002 A @500 nm
Display 6 inches high brightness Blue LCD display
Baseline Flatness ± 0.001 A
Detector Silicon photodiode
Power Supply AC 220/110 V, 50/60 Hz
Dimensions (L×W×H) 560×450×230 mm
Net Weight 28 kg
  • Compact, tabletop double beam designed UV-Vis spectrophotometer
    Silicon photodiode detector, Tungsten and Deuterium lamp as light source
    Wide wavelength range of 190 nm to 1100 nm with automatic setting
    6 inches high brightness blue LCD display
    Import source and receiver system
    Measurement methods: wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination, dual-wavelength, three-wavelength, DNA protein measurements etc.
    High performance and reliability with user-friendly interface

Double Beam UV-Visible Spectrophotometer are used for analysis of band gap, optical coatings and thin films, quantitative analyses, kinetics, wavelength scanning, and DNA and Protein analysis across biological research, bio-industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection, food hygiene, clinical examination, health and epidemic prevention and other fields.

{"Wavelength Range":"190 to 1100 nm","Spectral Bandwidth":"1.0 nm","Optical System":"Double beam","Wavelength Accuracy":"\u00b10.3 nm","Wavelength Repeatability":"\u22640.1 nm","Wavelength Resolution":"0.1 nm","Photometric Display Range":"-4 to 4 A","Photometric Mode":"T, A, C, E","Photometric Accuracy":"\u00b10.3% \u03c4 (0 to 100%\u03c4) \u00b1 0.002 A (0 to 0.5 A) \u00b1 0.003 A (0.5 A to 1 A)","Photometric Repeatability":"0.15% \u03c4 (0 to 100% \u03c4) \u00b1 0.001 A (0 to 0.5 A) \u00b1 0.0015 A (0.5 A to 1 A)","Light Source":"Tungsten lamp, Deuterium lamp","Stray Light":"\u22640.03% \u03c4 (220 nm NaI, 340 nm NaNO2<\/sub>)","Stability":"0.0005 A\/h @500 nm","Noise":"\u00b1 0.002 A @500 nm","Display":"6 inches high brightness Blue LCD display","Baseline Flatness":"\u00b1 0.001 A","Detector":"Silicon photodiode","Power Supply":"AC 220\/110 V, 50\/60 Hz","Dimensions (L\u00d7W\u00d7H)":"560\u00d7450\u00d7230 mm","Net Weight":"28 kg"}
Compact, tabletop double beam designed UV-Vis spectrophotometer
Silicon photodiode detector, Tungsten and Deuterium lamp as light source
Wide wavelength range of 190 nm to 1100 nm with automatic setting
6 inches high brightness blue LCD display
Import source and receiver system
Measurement methods: wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination, dual-wavelength, three-wavelength, DNA protein measurements etc.
High performance and reliability with user-friendly interface
Double Beam UV-Visible Spectrophotometer are used for analysis of band gap, optical coatings and thin films, quantitative analyses, kinetics, wavelength scanning, and DNA and Protein analysis across biological research, bio-industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection, food hygiene, clinical examination, health and epidemic prevention and other fields.


Related Products of Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer LUS-B31

Double Beam UV/Vis Spectrophotometer LUS-B31

Wavelength range : 190 to 1100 nm

Spectral bandwidth : 1 nm

Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Double Beam UV-Vis Spectrophotometer LUS-B40

Double Beam UV-Vis Spectrophotometer LUS-B40

Wavelength range : 190 to 1100 nm

Spectral bandwidth : 0.5/1/2/4 nm

Wavelength Accuracy : ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range

Double beam UV-Visible Spectrophotometer LUS-B15
Double beam UV-Visible Spectrophotometer LUS-B15

Wavelength range : 190 ~ 1100 nm

Spectral bandwidth : 2 nm

Wavelength accuracy : 0.5 nm

Double Beam UV/Vis Spectrophotometer LUS-B16
Double Beam UV/Vis Spectrophotometer LUS-B16

Wavelength Range : 190 ~ 1100 nm

Setting Wavelength : Automatic

Spectral Bandwidth : 0.5 / 1.0 / 2.0 / 4.0 nm adjustable

Double Beam UV-Vis Spectrophotometer LUS-B10

Double Beam UV-Vis Spectrophotometer LUS-B10

Wavelength Range : 190 to 1100 nm

Spectral Bandwidth : 1.8 nm

Optical System : Double beam

Double Beam UV-Vis Spectrophotometer LUS-B12

Double Beam UV-Vis Spectrophotometer LUS-B12

Wavelength Range : 190 to 1100 nm

Spectral Bandwidth : 1.8 nm

Optical System : Double beam, C-T monochromator,1200 L/mm holographic grating

Double Beam UV/Vis Spectrophotometer LUS-B32
Double Beam UV/Vis Spectrophotometer LUS-B32

Wavelength range : 190 to 1100 nm

Spectral bandwidth : 0.5/1/2/4/5 nm

Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Double Beam UV/Vis Spectrophotometer LUS-B30
Double Beam UV/Vis Spectrophotometer LUS-B30

Wavelength range : 190 to 1100 nm

Spectral bandwidth : 2 nm

Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-A10

Wavelength range 200 - 800 nm
Path length 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy ± 1 nm

Nano Spectrophotometer LNS-A21

Wavelength range 200 - 850 nm
Path length 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy ± 1 nm

Portable Spectrophotometer

Portable Spectrophotometer LSP-A30
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Portable Spectrophotometer LSP-A31
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode

NIR Spectrophotometer

NIR Spectrophotometer LNIR-A10

Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer LAAS-A13

Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm
Atomic Absorption Spectrophotometer LAAS-A11
Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy ≤ ± 0.5 nm

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer LFS-A10
Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm

Fluorescence Spectrophotometer LFS-A12

Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm

Talk to us?