Benchtop Ion meter for Br, LBIM-A14 comes with (Br) bromide ion selective electrode for bromide ion concentration measurement. This Ion meter comes with ± 0.5 % F.S. measurement accuracy. The direct ion concentration readout helps in elaborate measurement process. The system menu allows setting the 8 parameters like calibration points, stability condition etc. It can measure concentration in ppm, mg / L, mol / L. The mV measurement is used to check the performance of ion selective electrode.
Buy Now View CatalogIon measurement range | Br range: 5 × 106 - 1 M, 0.4 - 79900 ppm |
Ion measurement accuracy | ± 0.5 % F.S. |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration points | 2 to 5 points |
Calibration solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L |
mV range | (-1999.9) to 1999.9 mV |
mV accuracy | ± 0.2 mV |
mV resolution | 0.1 mV |
Temperature measurement range | 0 to 105 °C, 32 to 221 °F |
Temperature accuracy | ± 0.5 °C, ± 0.9 °F |
Temperature resolution | 0.1°C |
Temperature compensation | 0 to 100 °C, 32 to 212 °F |
Compensation mode | Manual or automatic |
Data hold function | Manual or automatic endpoint detection |
Reset function | Yes |
Stability condition | Low or high |
Calibration due | 0 to 31 days |
Power off | Manual or automatic (10,20,30 minutes) |
Memory | Stores up to 500 sets of data |
Output | USB communication interface |
Connector | BNC |
Display | LCD (130 × 110 mm) |
Power | DC 5 V, using AC adapter, AC 220 V / 50 Hz |
Dimension (L × W × H) | 210 × 188 × 60 mm |
Weight | 1.5 kg |
Benchtop Ion meter is used to measure the bromide ion concentration present in potable water, D/W water, waste water and natural water resources using different ion concentration electrodes.
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Ion measurement range : Pb range: 1×108 – 0.1M, 0.2-20700 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Ion measurement range : K range: 1×106 - 1M, 0.04 -39000 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Ion measurement range : Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Ion measurement range : NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Ion measurement range : F range: 1 × 106M – saturation, 0.02 ppm to saturation
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Ion measurement range : Cn range: 5 × 106 – 0.01 M, 0.2 – 260 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Ion measurement range : Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Ion measurement range : Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.5 mg / L |
Resolution | 0.1 mg / L |
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.2 mg / L |
Resolution | 0.01 mg / L |
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Conductivity measurement range | 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm |
Conductivity accuracy | ± 1 % F.S. |
Conductivity resolution | 0.01, 0.1, 1 |
Conductivity measurement range | 0.000 μS/cm to 3000mS/cm |
Resistivity measurement range | 5.00 Ω·cm to 100.0 MΩ·cm |
TDS measurement range | 0.000 mg/L to 1000g/L |
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Water hardness range |
0.05 mmol / L -0.2 mol / L (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f |
Accuracy | ± 1 % F.S. |
Calibration points | 2 to 5 points |
pH Mode |
|
||||||||||||||||||
mV Mode |
|
||||||||||||||||||
Conductivity Mode |
|
pH Mode |
|
||||||||||||||||||
mV Mode |
|
||||||||||||||||||
Conductivity Mode |
|
Determination range |
|
||
Measurement error | Less or less than 10 % | ||
Sample container/ bottle quantity | 1 to 6 |
Talk to us?