ICP Spectrometer LICP-A11 detects micro and macro elements using argon plasma with an analyzing rate of 15 elements per minute. Results can be achieved with lower levels of detection for qualitative and quantitative analysis. Detection of liquid flow from the spray chamber by optical drain sensor offers exceptional sensitivity and accuracy. Accurate signal-background ratio is attained by advanced control system.
Buy Now View CatalogWavelength range | 180 to 900 nm |
Elements per minute | 15 elements |
Temperature | 29 °C |
Incident slit | 25 µm |
Standard deviation | RSD ≤ 2 % |
Correlation coefficient | ≥ 0.9995 % |
Gas source | Argon ( 99.99 % ) |
Plasma gas flow meter | 100 – 1000 L / h ( 1.6 - 16 L / min ) |
Auxillary gas flow meter | 10 – 100 L / h ( 0.16 – 1.66 L / min ) |
Carrier gas flow meter | 0 ~ 5 L / min |
Cooling water flow rate | 5 L / min |
Cooling water temperature | 20 ~ 26 °C |
Water outlet diameter | 10 mm |
Line dispersion rate | 0.26 nm |
Resolving power | ≤ 0.007 nm |
Co-axial sprayer diameter | 6 mm |
Coil diameter | 25 mm |
Double room fog diameter | 34 mm |
Quartz tube torch diameter | 20 mm |
Mirror dimensions | 80 x 110 x 16 mm |
Used in clinical analysis for detection of metals in biological fluids , environmental analysis for trace element detection in water , soil , plants , pharmaceuticals for traces of catalysts and poison metals like Cd , Pb , industries for noble metal detection
Monochromator Specifications :
Solid State Power Specifications :
Technical Specifications :
Wavelength range : 195 to 800 mm
Elements per minute : 10 elements
Temperature range : 32 °C
Wavelength range ( 3600 lines / mm ) : 180 to 500 nm
Wavelength range ( 2400 lines / mm ) : 180 to 800 nm
Temperature : 20 ~ 28 °C
Analytical Method | Energy dispersive X-ray fluorescence analytical Method |
Elements Measuring | Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured |
Range | Simultaneous detector |
Measureable elements | S to U |
Detection limit | 1 ppm |
Temperature | 15 ~ 30 °C |
Angle Measurement Accuracy | 1inch | ||||||||||||||
Optical Parameter |
|
||||||||||||||
Divided Circle |
|
Beam Configuration | Dual Channel | ||||||||
Elements ( Measuring Range ) |
|
||||||||
Precision ( RSD ) | < 1.0 |
Spectral Range | 7800 cm-1 to 350 cm-1 |
Resolution | 0.85 cm-1 |
Wave number precision | ± 0.01 cm-1 |
X-ray Tuble | Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW |
Focus Size | 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm |
Stability | ≤ 0.01 % |