Labtron LLTT-A22 is manufactured with new-type compressor and has two cooling baths in one chamber. The instrument is specially designed and made as per ASTM D2386 Standard Test Method for Solidifying Point of Petroleum Products.
Buy Now View CatalogMeasurement range | |
Temperature controlling accuracy | ± 0.5 °C |
Refrigeration system | New-type refrigeration compressor |
Bath stirrer | |
Sample stirrer | |
Cold trough | One trough with two baths, temperatures in two baths are equal |
Controlling temperature of cold trough | Room temperature ~ (-70) °C |
Constant temperature bath Cubage | |
Constant temperature bath Types | |
Temperature Range | 20 °C ~ 80 °C |
Temperature sensor | |
Stirring motor Power | |
Stirring motor Speed | |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Refrigeration speed | |
Repeatability for solidifying point | |
Repeatability for pour point | |
Reproducibility | |
Pressure of cooling water | |
The lowest temperature | |
Sample cup Inner diameter | |
Sample cup Wall thickness | |
Sample cup Height | |
Pumping pressure | |
Dimensions | 730 x 580 x 520 mm |
Inner Dimensions | |
Outer Dimensions | |
Total power consumption | ≤ 1000 W |
Heating power | |
Power supply | AC 220 V ± 10 %, 50 Hz |
It is widely used in petroleum, chemical and research industry.
Freezing point range : -54°C to 2°C
Cold bath measurement temperature range : -70° to 20°C
Temperature controlling accuracy : ±0.5°C
Refrigeration system : New-type refrigeration compressor
Controlling temperature of cold trough : Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
Ambient temperature : ≤ 30 ℃
Temperature controlling accuracy : ± 0.5 °C
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Ambient temperature : (-10)℃ ~ 35 ℃
Relative humidity : ≤ 85 %
Sample cup Inner diameter : 31.0 ~ 32.0 mm
Chamber quantity : 2 chambers
Chamber 01 temperature control : Ambient to -51 ℃
Chamber 02 temperature control : Ambient to -65 ℃
Ambient temperature : ≤ 30 ℃
Refrigeration speed : > 40 °C / 10 min
Repeatability for solidifying point : ≤ 2 °C
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough : Room temperature ~ (-70) °C
Refrigeration system : New-type refrigeration compressor
Controlling temperature of cold trough : Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature : ≤ 30 ℃
Capacity | 2.0 kVA |
Speed of voltage increase | 2 k V/ s |
Voltage inspection accuracy | 0.01 |
Graduated flask | 100 ml,50 ml |
Conical flask | 100ml |
Separatory funnel | 250ml |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Precision of titration tube | Scale division is 0.02 ml |
Electric Muffle Furnace |
|
||||||||||||||||
Temperature controller |
|
||||||||||||||||
Electric heating plate |
|
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Measurement range | Room temperature ~ 150°C |
Stirring speed | 0 ~ 1200 r / min |
Heating power | 25 W |
Temperature controlling accuracy | ≤ 0.5 ℃ |
Temperature controlling range | Room temperature ~ 200 ℃ |
Power supply for illumination | 5 V |
Talk to us?