Labtron LLTT- A15 is manufactured with two cold trough with same temperature. The instrument is designed and made as per ASTM D2386 “Test Methods for Solidifying Point of Petroleum Products”, and ASTM D6371 “Test Methods for Cold Filter Plugging Point of Distillate Fuel
Buy Now View CatalogMeasurement range | |
Temperature controlling accuracy | |
Refrigeration system | New-type refrigeration compressor |
Bath stirrer | |
Sample stirrer | |
Cold trough | |
Controlling temperature of cold trough | Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C |
Constant temperature bath Cubage | |
Constant temperature bath Types | |
Temperature Range | |
Temperature sensor | |
Stirring motor Power | |
Stirring motor Speed | |
Ambient temperature | ≤ 30 ℃ |
Relative humidity | ≤ 85 % |
Refrigeration speed | |
Repeatability for solidifying point | |
Repeatability for pour point | |
Reproducibility | |
Pressure of cooling water | |
The lowest temperature | |
Sample cup Inner diameter | |
Sample cup Wall thickness | |
Sample cup Height | |
Pumping pressure | |
Dimensions | |
Inner Dimensions | 560 x 380 x 250 mm |
Outer Dimensions | 920 x 670 x 510 mm |
Total power consumption | ≤ 1500 W |
Heating power | |
Power supply | AC 220 V ± 10 %, 50 Hz |
It can be widely used in petroleum (solidifying point and cold filter plugging point), chemical industries, research and development laboratories.
Temperature controlling accuracy : ± 0.5 °C
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Refrigeration system : New-type refrigeration compressor
Controlling temperature of cold trough : Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
Ambient temperature : ≤ 30 ℃
Ambient temperature : ≤ 30 ℃
Refrigeration speed : > 40 °C / 10 min
Repeatability for solidifying point : ≤ 2 °C
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough : Room temperature ~ (-70) °C
Ambient temperature : (-10)℃ ~ 35 ℃
Relative humidity : ≤ 85 %
Sample cup Inner diameter : 31.0 ~ 32.0 mm
Chamber quantity : 2 chambers
Chamber 01 temperature control : Ambient to -51 ℃
Chamber 02 temperature control : Ambient to -65 ℃
Temperature controlling accuracy : ± 0.5 ℃
Refrigeration system : New-type refrigeration compressor
Cold trough : Two holes in one trough, and same temperature
Capacity : 20 L
Temperature range : Ambient +5°C to 100°C
Precision : ± 0.1℃
Measurement range | Room temperature ~ 150°C |
Stirring speed | 0 ~ 1200 r / min |
Heating power | 25 W |
Temperature controlling accuracy | ≤ 0.5 ℃ |
Temperature controlling range | Room temperature ~ 200 ℃ |
Power supply for illumination | 5 V |
Electric Muffle Furnace |
|
||||||||||||||||
Temperature controller |
|
||||||||||||||||
Electric heating plate |
|
Graduated flask | 100 ml,50 ml |
Conical flask | 100ml |
Separatory funnel | 250ml |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Precision of titration tube | Scale division is 0.02 ml |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Capacity | 2.0 kVA |
Speed of voltage increase | 2 k V/ s |
Voltage inspection accuracy | 0.01 |