Pour and Cloud Point Tester LLTT-A14 is a concise designed unit, made as per ASTM D97,ASTM D2500, ASTM D5853 Standard Test Method for Pour Point of Petroleum Oils and ASTM D5773, Standard Test Method of Cloud Point of Petroleum Products. Features two cooling bath chambers with temperature controller, ensures fast and high cooling efficiency. Equipped with new type of refrigeration compressor, the temperature of both cooling bath is same with ±1°C precision. With benchtop structure and easy usage, this pour and cloud point tester is suitable to determine pour point and cloud point of petroleum oils.
Buy Now View CatalogChamber quantity | 2 chambers |
Chamber 01 temperature control | Ambient to -51 ℃ |
Chamber 02 temperature control | Ambient to -65 ℃ |
Temperature precision | ±1°C |
Ambient temperature | ≤ 30°C |
Relative humidity | ≤ 85% |
Refrigeration system | New type refrigeration compressor |
Power supply | AC 220 V± 10%, 50 Hz |
Power | 1500 W |
Dimension (L×W×H) | 800×580×400 mm |
Weight | 32 kg |
Pour and cloud point tester is used for precise and convenient flow testing of petroleum products, biodiesel fuels, additives and lubricating oils etc.
Temperature controlling accuracy : ± 0.5 ℃
Refrigeration system : New-type refrigeration compressor
Cold trough : Two holes in one trough, and same temperature
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough : Room temperature ~ (-70) °C
Freezing point range : -54°C to 2°C
Cold bath measurement temperature range : -70° to 20°C
Temperature controlling accuracy : ±0.5°C
Temperature controlling accuracy : ± 0.5 °C
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Ambient temperature : (-10)℃ ~ 35 ℃
Relative humidity : ≤ 85 %
Sample cup Inner diameter : 31.0 ~ 32.0 mm
Temperature controlling accuracy : ± 0.5 °C
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Ambient temperature : ≤ 30 ℃
Refrigeration speed : > 40 °C / 10 min
Repeatability for solidifying point : ≤ 2 °C
Refrigeration system : New-type refrigeration compressor
Controlling temperature of cold trough : Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature : ≤ 30 ℃
Electric Muffle Furnace |
|
||||||||||||||||
Temperature controller |
|
||||||||||||||||
Electric heating plate |
|
Measurement range | Room temperature ~ 150°C |
Stirring speed | 0 ~ 1200 r / min |
Heating power | 25 W |
Temperature controlling accuracy | ≤ 0.5 ℃ |
Temperature controlling range | Room temperature ~ 200 ℃ |
Power supply for illumination | 5 V |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Precision of titration tube | Scale division is 0.02 ml |
Graduated flask | 100 ml,50 ml |
Conical flask | 100ml |
Separatory funnel | 250ml |
Capacity | 2.0 kVA |
Speed of voltage increase | 2 k V/ s |
Voltage inspection accuracy | 0.01 |