Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21

Labtron LLTT- A21 is manufactured with new-type compressor, advanced temperature controller and special cooling bath. The instrument is designed and made as per ASTM D2386 “Test Methods for Solidifying Point of Petroleum Products”, and ASTM D6371 “Test Methods for Cold Filter Plugging Point of Distillate Fuels”.

Buy Now View Catalog
Measurement range
Temperature controlling accuracy
Refrigeration system New-type refrigeration compressor
Bath stirrer
Sample stirrer
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Constant temperature bath Cubage
Constant temperature bath Types
Temperature Range
Temperature sensor
Stirring motor Power
Stirring motor Speed
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Refrigeration speed
Repeatability for solidifying point
Repeatability for pour point
Reproducibility
Pressure of cooling water
The lowest temperature
Sample cup Inner diameter
Sample cup Wall thickness
Sample cup Height
Pumping pressure
Dimensions
Inner Dimensions 560 x 380 x 250 mm
Outer Dimensions 730 x 580 x 520 mm
Total power consumption ≤ 1000 W
Heating power
Power supply
  • New-type compressor and progressed temperature controller Workbench is made up of stainless steel to avoid corrosion Unique cooling bath Two cooling baths in one chamber with high efficiency and faster cooling rate High temperature solidifying point

It is widely used in petroleum, chemical and research industry. It is also suitable to determine solidifying point and cold filter plugging point of petroleum products.

{"Measurement range":"","Temperature controlling accuracy":"","Refrigeration system":"New-type refrigeration compressor","Bath stirrer":"","Sample stirrer":"","Cold trough":"One trough with two baths, temperatures in two baths are equal","Controlling temperature of cold trough":"Room temperature ~ (-70) \u00b0C","Constant temperature bath Cubage":"","Constant temperature bath Types":"","Temperature Range":"","Temperature sensor":"","Stirring motor Power":"","Stirring motor Speed":"","Ambient temperature":"\u2264 30 \u2103","Relative humidity":"\u2264 85 %","Refrigeration speed":"","Repeatability for solidifying point":"","Repeatability for pour point":"","Reproducibility":"","Pressure of cooling water":"","The lowest temperature":"","Sample cup Inner diameter":"","Sample cup Wall thickness":"","Sample cup Height":"","Pumping pressure":"","Dimensions":"","Inner Dimensions":"560 x 380 x 250 mm","Outer Dimensions":"730 x 580 x 520 mm","Total power consumption":"\u2264 1000 W","Heating power":"","Power supply":""}
New-type compressor and progressed temperature controller Workbench is made up of stainless steel to avoid corrosion Unique cooling bath Two cooling baths in one chamber with high efficiency and faster cooling rate High temperature solidifying point
It is widely used in petroleum, chemical and research industry. It is also suitable to determine solidifying point and cold filter plugging point of petroleum products.


Related Products of Low Temperature Tester

Solidifying Point Tester LLTT-A13

Solidifying Point Tester LLTT-A13

Temperature controlling accuracy : ± 0.5 ℃

Refrigeration system : New-type refrigeration compressor

Cold trough : Two holes in one trough, and same temperature

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

Ambient temperature : (-10)℃ ~ 35 ℃

Relative humidity : ≤ 85 %

Sample cup Inner diameter : 31.0 ~ 32.0 mm

Pour and Cloud Point Tester LLTT-A14
Pour and Cloud Point Tester LLTT-A14

Chamber quantity : 2 chambers

Chamber 01 temperature control : Ambient to -51 ℃

Chamber 02 temperature control : Ambient to -65 ℃

Freezing Point Tester LLTT-A11
Freezing Point Tester LLTT-A11

Freezing point range : -54°C to 2°C

Cold bath measurement temperature range : -70° to 20°C

Temperature controlling accuracy : ±0.5°C

Solidifying Point Tester LLTT-A20

Solidifying Point Tester LLTT-A20

Temperature controlling accuracy : ± 0.5 °C

Refrigeration system : New-type refrigeration compressor

Cold trough : One trough with two baths, temperatures in two baths are equal

Automatic Pour Point Tester LLTT-A23

Automatic Pour Point Tester LLTT-A23

Ambient temperature : ≤ 30 ℃

Refrigeration speed : > 40 °C / 10 min

Repeatability for solidifying point : ≤ 2 °C

Solidifying Point Tester ('-20°C +80°C') LLTT-A22
Solidifying Point Tester ('-20°C +80°C') LLTT-A22

Temperature controlling accuracy : ± 0.5 °C

Refrigeration system : New-type refrigeration compressor

Cold trough : One trough with two baths, temperatures in two baths are equal

Multifunctional Low Temperature Tester LLTT-A16
Multifunctional Low Temperature Tester LLTT-A16

Refrigeration system : New-type refrigeration compressor

Controlling temperature of cold trough : Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C

Ambient temperature : ≤ 30 ℃

Ash Content Tester

Ash Content Tester LACT-A10

Electric Muffle Furnace
Controlled temperature 775 ±25 ℃
Temperature rising time of empty chamber ≤ 50 min
Furnace temperature uniformity ≤ 15℃
Internal dimension 200 × 120 × 80 mm
External dimension 490 × 490 × 450 mm
Power consumption 2.5 kW
Power supply AC 220V ±10%, 50 Hz
Net weight 35 kg
Temperature controller
Maximum control temperature 1200 ℃
Dimension 500 × 300 × 235 mm
Power consumption 5000 W
Power supply AC 220±10% V, 50Hz
Net weight 5 kg
Electric heating plate
Heating power (1 to 6) grades, continuously adjustable
Temperature 400℃
Diameter of heating plate Φ 180 mm
Dimension 280 × 250 × 90 mm
Power consumption 2000 W
Power supply AC 220±10%V, 50Hz

Acid and Alkali Tester

Water Soluble Acid and Alkali Tester LAAT-A10

Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Acid Number and Acidity Tester LAAT-A11
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A10
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg

Automatic Bomb Calorimeter LABC-A11

Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W
Aniline Point Tester LAPT-A11
Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V

Automatic Dielectric Tester

Automatic Dielectric Tester LADT-A10
Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01