Portable Vibration Calibrator LPVC-A10 is a tabletop unit with standard sine signals at continually varying frequency from 10 Hz to 1280 Hz. LCD digital panel displays defined amplitude of the acceleration, velocity and displacement. Either horizontal or vertical vibration can be generated. It is an all in one unit combining sine signal generator, power amplifier, standard transducer and a shaker.
Buy Now View CatalogFrequency (continually adjustable) | 10 Hz to1280 Hz + 0.01 % |
Amplitude acceleration ( at 30m/s2 pk ) | 40 Hz to 320 Hz + 0.3 dB + 1 digit |
Amplitude velocity ( at 25mm / sec pk ) | 40 Hz to 320 Hz + 0.5dB +1 digit |
Amplitude displacement ( at 50 μm pk-pk ) | 40 Hz to 320 Hz + 0.5 dB + 1 digit |
Probe | 5 mm , 8 mm and 11mm probe |
Probe range | 0 ~ 2.0 mm |
Display | 3 ½ digit display |
Storage | -20 °C to 70 °C |
Operational temperature | 0 °C to 50 °C |
Humidity | 90 % non-condensing |
Dimensions | 280 x 180 x 250 mm |
Weight | 9 kgs |
Used to calibrate vibration monitoring / measuring instruments or data acquisition / data collector devices
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Brinell hardness test : 306, 613, 1839 N
Test force : 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
Hardness value symbol : HV1, HV5, HV10, HV20, HV30, HV250
Error range in display : ± 3.0 %, ± 2.0 %
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Total test force dwell time : 0 to 30 S
Test force : 612.5 N, 980 N, 1225 N
Brinell hardness test : 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N
Hardness measuring area : 8 to 650 HBW (hard metals steel ball)
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Total test force dwell time : 1 to 30 S
Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
Temperature range | RT to 300°C |
Temperature control system | PID control |
Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
Temperature accuracy | ± 0.3 ℃ |
Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
The maximum temperature | 300°C |
Temperature fluctuation | Within ± 0.5°C |
Temperature uniformity | Within ± 1°C |
Vacuum degree | 0 to 90 KPa |
Accuracy | 1 % FS |
Resolution | 0.1 KPa |
Test angle | 60° |
Gloss aperture | 2 × 3 mm |
Measurement range | 0 to 1000 GU |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
Stability | ≤ 0.1 within 30 min |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
Light source | D65 as illuminating source |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |