Soil nutrient tester TSNA-A11

Soil nutrient tester TSNA-A11 with microprocessor controlled technology measures nutrient values in % and gives accurate test results. The optical filter present in the nutrient analyzer acts as light source. It has attractive & durable, long lasting plate shell, large LCD display to easily view & study test parameters. With time display function, it can automatically record and save the time of sample tested.

Buy Now View Catalog
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Wavelength range Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm
Sensitivity Red light: ≥ 4.5 × 10-5 , Blue light: ≥ 3.17 × 10-3
Moisture measure range A: humidity 0 to 100 %, B: Accuracy: ±3 %
Measurement time (for soil N, P, K) ≤30 min
5 pcs soil samples at one time ≤50 min (including pretreatment time)
Soil moisture mode
  • Moisture content rate testing range: 0 to 100 %
  • Moisture unit: % (m3 /m3)
  • Accuracy: ± 2 %
pH mode
  • pH Measurement range: 1 to 14 pH
  • pH Accuracy: ± 0.1
Salinity mode
  • Salinity range: 0.01 % to 1.00 %
  • Salinity accuracy: ± 5 %
Dimension 340×280×100 mm
Gross weight 18 kg
Power supply AC 180 to 240 V, 50 Hz
  • Large LCD display
    Playback function for convenient testing
    Built –in rechargeable battery
    Built-in thermal printer
    1000 groups of data storage
    Microprocessor controlled technology
Reagent as per requirement/need

It finds best application in quantitative analysis of to N, P, K, organic matter, pH, trace elements, salinity of soil, fertilizer & other samples.

{"Measuring range":"0.001 to 9999","Stability":"A (absorbency of light) <0.003 within 3 mins","Linearity error":"<3.0 %","Repeatability error":"A (absorbency of light) <0.005","Wavelength range":"Red light: 680 \u00b1 2 nm, Blue light: 420 \u00b1 2 nm, Green light: 510 \u00b1 2 nm","Sensitivity":"Red light: \u2265 4.5 \u00d7 10-5<\/sup> , Blue light: \u2265 3.17 \u00d7 10-3<\/sup>","Moisture measure range":"A: humidity 0 to 100 %, B: Accuracy: \u00b13 %","Measurement time (for soil N, P, K)":"\u226430 min 5 pcs soil samples at one time \u226450 min (including pretreatment time)","Soil moisture mode":{"Moisture content rate testing range":"0 to 100 %","Moisture unit":"% (m3<\/sup> \/m3<\/sup>)","Accuracy":"\u00b1 2 %"},"pH mode":{"pH Measurement range":"1 to 14 pH","pH Accuracy":"\u00b1 0.1"},"Salinity mode":{"Salinity range":"0.01 % to 1.00 %","Salinity accuracy":"\u00b1 5 %"},"Dimension":"340\u00d7280\u00d7100 mm","Gross weight":"18 kg","Power supply":"AC 180 to 240 V, 50 Hz"}
Large LCD display
Playback function for convenient testing
Built –in rechargeable battery
Built-in thermal printer
1000 groups of data storage
Microprocessor controlled technology
It finds best application in quantitative analysis of to N, P, K, organic matter, pH, trace elements, salinity of soil, fertilizer & other samples.


Related Products of Soil Testing Instruments

Soil moisture meter TSMM-A10

Soil moisture meter TSMM-A10

Measurement range : 0 to 80 %

Resolution : 0.1

Accuracy : ± 2 % n (non-saturation condition)

Soil water hardness meter TSHM-A11

Soil water hardness meter TSHM-A11

Maximum load : 100 kg ( kg and N can be switched automatically)

Resolution : 0.01 g

Accuracy : ± 0.5 %

Soil nutrient tester TSNA-A10
Soil nutrient tester TSNA-A10

Measuring range : 0.001 to 9999

Stability : A (absorbency of light) <0.003 within 3 mins

Linearity error : <3.0 %

Soil moisture meter TSMM-A12
Soil moisture meter TSMM-A12

Measurement range : 0 to 60 %

Resolution : 0.1

Accuracy : ± 5 % n (non-saturation condition)

Soil water hardness meter TSHM-A10

Soil water hardness meter TSHM-A10

Maximum load : 100 kg ( kg and N can be switched automatically)

Resolution : 0.01 g

Accuracy : ± 0.5 %

Soil moisture meter TSMM-A11

Soil moisture meter TSMM-A11

Measurement range : 0 to 90 %

Resolution : 0.1 or 0.01

Accuracy : ± 5 % n (non-saturation condition)

Soil Water potential tester TSWT-A10
Soil Water potential tester TSWT-A10

Measuring range : 0 to 100 kPa

Resolution : 0.01 kPa

Accuracy : ± 1 kPa

Soil Salinity tester TSST-A10
Soil Salinity tester TSST-A10

Salinity Measurement range : 0.00 to 19.99 ms/cm

Measuring accuracy : EC ± 2% full scale

Temperature Measurement range : -5 to 50°C

Paper Testing Instruments

Whiteness and chromaticity tester TP-A10

Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min

Whiteness meter TP-A11

Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source

NDT Testing Instruments

Rockwell hardness meter TRHM-A11
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S
Rockwell hardness meter TRHM-A10
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S

Other Testing Instruments

Benchtop gloss meter TBGM-A10

Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU

Plastic Testing Instruments

Aging Oven TAO-A10

The maximum temperature 300°C
Temperature fluctuation Within ± 0.5°C
Temperature uniformity Within ± 1°C
Vacuum Leak Tester TVLT-A10
Vacuum degree 0 to 90 KPa
Accuracy 1 % FS
Resolution 0.1 KPa

Rubber Testing Instruments

Three roll mill machine TRMM-A10
Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control

Rubber Low Temperature Brittleness Tester TRBT-A11

Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min
-30℃ to -40℃ around 2.5 ℃/min
-40℃ to -70℃ around 2.0 ℃/min

Talk to us?