Soil Water potential tester TSWT-A10 with high resolution display, measures soil temperature & soil water potential at the same time. This portable soil water potential, automatically obtains the peak data of water potential & provides highly accurate & reliable readings. Equipped with low voltage tips helps in accurate moisture (water potential) measurement of moist, dry, normal soil.
Buy Now View Catalog| Measuring range | 0 to 100 kPa |
| Resolution | 0.01 kPa |
| Accuracy | ± 1 kPa |
| Soil temperature measuring range | -55 to 105°C |
| Temperature accuracy | ± 1°C |
| Probe Quantity | 3 pcs |
| Storage memory | 200 groups of data |
| Gross Weight | 15 kg |
It finds best applications in the agriculture, farming, gardening, soil testing industry for research & quality purpose.
Maximum load : 100 kg ( kg and N can be switched automatically)
Resolution : 0.01 g
Accuracy : ± 0.5 %
Measurement range : 0 to 60 %
Resolution : 0.1
Accuracy : ± 5 % n (non-saturation condition)
Salinity Measurement range : 0.00 to 19.99 ms/cm
Measuring accuracy : EC ± 2% full scale
Temperature Measurement range : -5 to 50°C
Measuring range : 0.001 to 9999
Stability : A (absorbency of light) <0.003 within 3 mins
Linearity error : <3.0 %
Measurement range : 0 to 90 %
Resolution : 0.1 or 0.01
Accuracy : ± 5 % n (non-saturation condition)
Measuring range : 0.001 to 9999
Stability : A (absorbency of light) <0.003 within 3 mins
Linearity error : <3.0 %
Maximum load : 100 kg ( kg and N can be switched automatically)
Resolution : 0.01 g
Accuracy : ± 0.5 %
Measurement range : 0 to 80 %
Resolution : 0.1
Accuracy : ± 2 % n (non-saturation condition)
| Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
| Temperature range | RT to 300°C |
| Temperature control system | PID control |
| Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
| Temperature accuracy | ± 0.3 ℃ |
| Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
| Test angle | 60° |
| Gloss aperture | 2 × 3 mm |
| Measurement range | 0 to 1000 GU |
| Vacuum degree | 0 to 90 KPa |
| Accuracy | 1 % FS |
| Resolution | 0.1 KPa |
| The maximum temperature | 300°C |
| Temperature fluctuation | Within ± 0.5°C |
| Temperature uniformity | Within ± 1°C |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 1 to 30 S |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 0 to 30 S |
| Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
| System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
| Light source | D65 as illuminating source |
| Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
| Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
| Stability | ≤ 0.1 within 30 min |