Rubber low temperature brittleness tester TRBT-A11 is specialised to study the effects of low temperature on rubber. This is achieved when vulcanized rubber is exposed to damage via an impact from test conditions; which is therefore called as brittle temperature. It identifies the difference between non-rigid plastic on exposure to low temperature. Flexible in evaluating low temperature performance quality of different types of vulcanized rubber materials which is essential in production process.
Buy Now View CatalogTemperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
Temperature accuracy | ± 0.3 ℃ |
Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
Max dimension L × W × H | 910 × 510 × 860 mm |
Effective test space of the chamber L × W × H | 280 × 170 × 120 mm |
Digital timer | 0 s to 99 min |
Time resolution | 1 s |
Cooling medium | Ethanol or other non-freezing liquid |
Stirring motor | 8 W |
Power supply | 220 V to 240 V ; 50 Hz; 1.5 kW |
Working temperature | ≤ 25 |
Applicable in scientific research testing, quality analysis, inspection units to measure highest temperature of vulcanized rubber and other materials.
Temperature range : -60°C to 0°C
Temperature accuracy : ± 0.5°C
Impact speed : 2 m/s ± 0.2 m/s
Control temperature range : Normal temperature to 200°C
Temperature display resolution : 0.01°C
Temperature control accuracy : ± 0.3°
Temperature range : RT 50° to 300°
Temperature accuracy : ± 1°
Measuring range : 0.01 to 25 mm
Mixed capacity : 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range : RT to 300°C
Temperature control system : PID control
Temperature tester : Room temperature to 200°C
Temperature display resolution : 0.1°C
Temperature control accuracy : ≤ ± 0.3°C
Test arm weight : 2.5 N
Additional Loads : 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler : 150 mm
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
Light source | D65 as illuminating source |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
Stability | ≤ 0.1 within 30 min |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 1 to 30 S |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 0 to 30 S |
The maximum temperature | 300°C |
Temperature fluctuation | Within ± 0.5°C |
Temperature uniformity | Within ± 1°C |
Vacuum degree | 0 to 90 KPa |
Accuracy | 1 % FS |
Resolution | 0.1 KPa |
Test angle | 60° |
Gloss aperture | 2 × 3 mm |
Measurement range | 0 to 1000 GU |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |