Rubber-weiss plasticity testing machine TRWM-A10 the pressurized heavy hammer slides moves in up and down axial direction to measure the deformation occurred due to heavy pressure hammer displacement. 3 minutes after completion of the test, clock stops automatically, bringing hammer back to normal position. The dial indicator fixed on the top bracket of TRWM-A10 measures the sample deformation caused by heavy pressure hammer displacement.
Buy Now View Catalog| Temperature range | RT 50° to 300° |
| Temperature accuracy | ± 1° |
| Measuring range | 0.01 to 25 mm |
| Accuracy | ± 0.01 mm |
| Load | 49 N ± 0.05 N |
| Counter | LCD display |
| Impact speed | |
| Temperature fluctuation | |
| Distance between center of impact or bottom of gripper | |
| Outer dimension | |
| Cold well volume | |
| Dimension | 350×350×350 mm |
| Power | AC 220 V, 5A |
| Net weight | 53 kg |
Rubber-Weiss plasticity testing machine finds applications in rubber & rubber like material industry.
Temperature tester : Room temperature to 200°C
Temperature display resolution : 0.1°C
Temperature control accuracy : ≤ ± 0.3°C
Temperature range : -60°C to 0°C
Temperature accuracy : ± 0.5°C
Impact speed : 2 m/s ± 0.2 m/s
Temperature control range : Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy : ± 0.3 ℃
Impact speed : 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min
Control temperature range : Normal temperature to 200°C
Temperature display resolution : 0.01°C
Temperature control accuracy : ± 0.3°
Mixed capacity : 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range : RT to 300°C
Temperature control system : PID control
Test arm weight : 2.5 N
Additional Loads : 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler : 150 mm
| Test angle | 60° |
| Gloss aperture | 2 × 3 mm |
| Measurement range | 0 to 1000 GU |
| Vacuum degree | 0 to 90 KPa |
| Accuracy | 1 % FS |
| Resolution | 0.1 KPa |
| The maximum temperature | 300°C |
| Temperature fluctuation | Within ± 0.5°C |
| Temperature uniformity | Within ± 1°C |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 1 to 30 S |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 0 to 30 S |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
| Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
| Stability | ≤ 0.1 within 30 min |
| Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
| System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
| Light source | D65 as illuminating source |