Rockwell hardness meter TRHM-A11 is a mechanical & electrical hardness testing instrument with novel design, digital display and micro-processor controlled loading system. Its automatic loading control eliminates operational errors in reading. It is used for the testing of ferrous & non-ferrous materials, plastic materials at Rockwell scale. The digital display shows test force values, dwell time, unloading, hardness results, conversion table etc. to study.
Buy Now View CatalogPreliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Brinell hardness test | |
Vickers hardness test | |
Magnification of Microscope | |
Total test force dwell time | 1 to 30 S |
Hardness indication | Digital display |
Resolution | 0.1 HR |
Loading control | Automatic |
Maximum height of specimens | 170 mm |
Distance from Indenter’s center to outer wall | 165 mm |
Range of Rockwell hardness value |
HRA 20 to 88 HRB 20 to 100 HRC 20 to 70 |
Dimension of the machine | 490 × 212 × 750 mm |
Weight | 85 kg |
Power supply | AC 220 V , 50 Hz |
Rockwell hardness tester with digital display has applications in workshops, inspection and production, and plastic industry.
Test force : 612.5 N, 980 N, 1225 N
Brinell hardness test : 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N
Hardness measuring area : 8 to 650 HBW (hard metals steel ball)
Test force : 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
Hardness value symbol : HV1, HV5, HV10, HV20, HV30, HV250
Error range in display : ± 3.0 %, ± 2.0 %
Frequency (continually adjustable) : 10 Hz to1280 Hz + 0.01 %
Amplitude acceleration ( at 30m/s2 pk ) : 40 Hz to 320 Hz + 0.3 dB + 1 digit
Amplitude velocity ( at 25mm / sec pk ) : 40 Hz to 320 Hz + 0.5dB +1 digit
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Total test force dwell time : 0 to 30 S
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Brinell hardness test : 306, 613, 1839 N
Test angle | 60° |
Gloss aperture | 2 × 3 mm |
Measurement range | 0 to 1000 GU |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
Temperature accuracy | ± 0.3 ℃ |
Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
Temperature range | RT to 300°C |
Temperature control system | PID control |
Vacuum degree | 0 to 90 KPa |
Accuracy | 1 % FS |
Resolution | 0.1 KPa |
The maximum temperature | 300°C |
Temperature fluctuation | Within ± 0.5°C |
Temperature uniformity | Within ± 1°C |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
Stability | ≤ 0.1 within 30 min |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
Light source | D65 as illuminating source |
Talk to us?