Soil nutrient tester TSNA-A10 with microprocessor controlled technology measures nutrient values in % and gives accurate test results. Its LCD touch display shows all test parameters, test results, which can be printed out using built-in printer. The optical filter present in the nutrient analyzer acts as light source, its silicon semiconductor acts as signal receiver system with 100000 hours of work life.
Buy Now View CatalogMeasuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Repeatability error | A (absorbency of light) <0.005 |
Wavelength range | Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm, Orange light: 590 ± 2 nm |
Sensitivity | Red light: ≥ 4.5 × 10-5 , Blue light: ≥ 3.17 × 10-3 , Green light: ≥ 2.35 × 10-3 , Orange light: ≥ 2.13 × 10-3 |
Moisture measure range | A: humidity 0 to 100 %, B: Accuracy: ±3 % |
Measurement time (for soil N, P, K) |
≤30 min 5 pcs soil samples at one time ≤50 min (including pretreatment time) |
Soil moisture mode |
|
pH mode |
|
Conductivity mode |
|
Dimension | 340 × 280 × 100 mm |
Gross Weight | 15 kg |
Power supply | AC 180 to 240 V, 50 Hz |
It finds best application in quantitative analysis of to N, P, K, organic matter, pH, trace elements, salinity of soil, fertilizer & other samples.
Measuring range : 0.001 to 9999
Stability : A (absorbency of light) <0.003 within 3 mins
Linearity error : <3.0 %
Salinity Measurement range : 0.00 to 19.99 ms/cm
Measuring accuracy : EC ± 2% full scale
Temperature Measurement range : -5 to 50°C
Measurement range : 0 to 60 %
Resolution : 0.1
Accuracy : ± 5 % n (non-saturation condition)
Measurement range : 0 to 90 %
Resolution : 0.1 or 0.01
Accuracy : ± 5 % n (non-saturation condition)
Measurement range : 0 to 80 %
Resolution : 0.1
Accuracy : ± 2 % n (non-saturation condition)
Measuring range : 0 to 100 kPa
Resolution : 0.01 kPa
Accuracy : ± 1 kPa
Maximum load : 100 kg ( kg and N can be switched automatically)
Resolution : 0.01 g
Accuracy : ± 0.5 %
Maximum load : 100 kg ( kg and N can be switched automatically)
Resolution : 0.01 g
Accuracy : ± 0.5 %
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
Stability | ≤ 0.1 within 30 min |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
Light source | D65 as illuminating source |
The maximum temperature | 300°C |
Temperature fluctuation | Within ± 0.5°C |
Temperature uniformity | Within ± 1°C |
Vacuum degree | 0 to 90 KPa |
Accuracy | 1 % FS |
Resolution | 0.1 KPa |
Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
Temperature range | RT to 300°C |
Temperature control system | PID control |
Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
Temperature accuracy | ± 0.3 ℃ |
Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
Test angle | 60° |
Gloss aperture | 2 × 3 mm |
Measurement range | 0 to 1000 GU |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 0 to 30 S |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 1 to 30 S |