Three roll mill machine TRMM-A10 is used for homogeneous mixing of rubber, PVC materials master-batch & other chemical raw materials. The raw material is mixed with the mixing agent to achieve the desired color & quality. The stainless steel, hard chromium plating rolls space can be manually adjusted according to the users need with 0.1 to 7 mm spacing. It finds application in rubber & plastic industry.
Buy Now View Catalog| Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
| Temperature range | RT to 300°C |
| Temperature control system | PID control |
| Display | LED display |
| Heater | Cylindrical mold |
| Warm-up line | R.T. to 150°C for about 20 min |
| Temperature accuracy | ± 3°C |
| Roller specifications |
|
| Weight | 750 kg |
| Power | 7 kW |
| Power supply | AC380V, 50 Hz, 3 Phase, 26A |
Three roll mill machine is widely used in Rubber & plastic industry.
Temperature range : -60°C to 0°C
Temperature accuracy : ± 0.5°C
Impact speed : 2 m/s ± 0.2 m/s
Temperature control range : Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy : ± 0.3 ℃
Impact speed : 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min
Temperature tester : Room temperature to 200°C
Temperature display resolution : 0.1°C
Temperature control accuracy : ≤ ± 0.3°C
Temperature range : RT 50° to 300°
Temperature accuracy : ± 1°
Measuring range : 0.01 to 25 mm
Test arm weight : 2.5 N
Additional Loads : 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler : 150 mm
Control temperature range : Normal temperature to 200°C
Temperature display resolution : 0.01°C
Temperature control accuracy : ± 0.3°
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 1 to 30 S |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 0 to 30 S |
| The maximum temperature | 300°C |
| Temperature fluctuation | Within ± 0.5°C |
| Temperature uniformity | Within ± 1°C |
| Vacuum degree | 0 to 90 KPa |
| Accuracy | 1 % FS |
| Resolution | 0.1 KPa |
| Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
| System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
| Light source | D65 as illuminating source |
| Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
| Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
| Stability | ≤ 0.1 within 30 min |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Test angle | 60° |
| Gloss aperture | 2 × 3 mm |
| Measurement range | 0 to 1000 GU |