Three roll mill machine TRMM-A10 is used for homogeneous mixing of rubber, PVC materials master-batch & other chemical raw materials. The raw material is mixed with the mixing agent to achieve the desired color & quality. The stainless steel, hard chromium plating rolls space can be manually adjusted according to the users need with 0.1 to 7 mm spacing. It finds application in rubber & plastic industry.
Buy Now View CatalogMixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
Temperature range | RT to 300°C |
Temperature control system | PID control |
Display | LED display |
Heater | Cylindrical mold |
Warm-up line | R.T. to 150°C for about 20 min |
Temperature accuracy | ± 3°C |
Roller specifications |
|
Weight | 750 kg |
Power | 7 kW |
Power supply | AC380V, 50 Hz, 3 Phase, 26A |
Three roll mill machine is widely used in Rubber & plastic industry.
Test arm weight : 2.5 N
Additional Loads : 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler : 150 mm
Temperature control range : Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy : ± 0.3 ℃
Impact speed : 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min
Temperature range : RT 50° to 300°
Temperature accuracy : ± 1°
Measuring range : 0.01 to 25 mm
Temperature range : -60°C to 0°C
Temperature accuracy : ± 0.5°C
Impact speed : 2 m/s ± 0.2 m/s
Control temperature range : Normal temperature to 200°C
Temperature display resolution : 0.01°C
Temperature control accuracy : ± 0.3°
Temperature tester : Room temperature to 200°C
Temperature display resolution : 0.1°C
Temperature control accuracy : ≤ ± 0.3°C
Vacuum degree | 0 to 90 KPa |
Accuracy | 1 % FS |
Resolution | 0.1 KPa |
The maximum temperature | 300°C |
Temperature fluctuation | Within ± 0.5°C |
Temperature uniformity | Within ± 1°C |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
Stability | ≤ 0.1 within 30 min |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
Light source | D65 as illuminating source |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 1 to 30 S |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 0 to 30 S |
Test angle | 60° |
Gloss aperture | 2 × 3 mm |
Measurement range | 0 to 1000 GU |
Talk to us?