Mooney viscometer TMV-A10 is designed to measure the change in elastomers properties, viscosity, scorch time & cure rates of rubber & plastic. With strong data function, mooney viscometer supports storage, drawing and output of multiple curves under the same interface. The resistance to rotation from the elastomer is, its shearing viscosity proportional to mean absolute viscosity of the specimen.
Buy Now View Catalog| Test arm weight | |
| Additional Loads | |
| Idler | |
| Abrasion stroke | |
| Horizontal displacement | |
| Stroke | |
| Grips lateral displacement | |
| Idler wheel speed | |
| Measurement mode | |
| Specimen size | |
| Emery cloth specifications | |
| Shift screw | |
| Limit rotation | |
| Set rotation | |
| Return form | |
| Net Weight | |
| Dimension | |
| Control temperature range | Normal temperature to 200°C |
| Temperature tester | |
| Temperature display resolution | 0.01°C |
| Temperature control accuracy | ± 0.3° |
| Calibration accuracy | Mooney value ± 0.5 |
| Rotor speed | 2 rpm |
| Die cavity frequency | |
| Sway angle | |
| Air compression | |
| Ambient temperature | |
| Test result | |
| Display | |
| Speed accuracy | ± 0.02 rpm |
| Torque range | Mooney value 0 to 200 |
| Torque resolution | Mooney value 0.1 |
| Printer connection | Yes |
| Content printed | Data, time, temperature, mooney scorch curve & MV , T5 T35 T3 T18 @15 @30 |
| Product dimension | |
| Weight | |
| Power supply | AC 220 V, 50 Hz, ± 10 % |
The Mooney viscometer is used in rubber & plastic industry for quality & research testing of elastomers, polymers.
Temperature range : RT 50° to 300°
Temperature accuracy : ± 1°
Measuring range : 0.01 to 25 mm
Temperature range : -60°C to 0°C
Temperature accuracy : ± 0.5°C
Impact speed : 2 m/s ± 0.2 m/s
Temperature control range : Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy : ± 0.3 ℃
Impact speed : 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min
Mixed capacity : 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range : RT to 300°C
Temperature control system : PID control
Test arm weight : 2.5 N
Additional Loads : 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler : 150 mm
Temperature tester : Room temperature to 200°C
Temperature display resolution : 0.1°C
Temperature control accuracy : ≤ ± 0.3°C
| Test angle | 60° |
| Gloss aperture | 2 × 3 mm |
| Measurement range | 0 to 1000 GU |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 0 to 30 S |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 1 to 30 S |
| Vacuum degree | 0 to 90 KPa |
| Accuracy | 1 % FS |
| Resolution | 0.1 KPa |
| The maximum temperature | 300°C |
| Temperature fluctuation | Within ± 0.5°C |
| Temperature uniformity | Within ± 1°C |
| Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
| Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
| Stability | ≤ 0.1 within 30 min |
| Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
| System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
| Light source | D65 as illuminating source |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |