Rubber low temperature brittleness tester TRBT-A10 measures the highest temperature when vulcanized rubber is damaged due to an impact from test conditions, this temperature is called as brittle temperature. It identifies the difference between non-rigid plastic, flexible materials under low temperature. It also measures the brittle & low temperature performance quality of different types of vulcanized rubber materials.

Buy Now View Catalog
Temperature range -60°C to 0°C
Temperature accuracy ± 0.5°C
Measuring range
Accuracy
Load
Counter
Impact speed 2 m/s ± 0.2 m/s
Temperature fluctuation <± 0.5°C
Distance between center of impact or bottom of gripper 11 ± 0.5 mm
Outer dimension 720×700×1380 mm
Cold well volume 700 ml
Dimension
Power 1100 W
Net weight 180 kg
  • Analogue display to observe temperature value
    -60°C to 0°C low temperature range
    Indications for highest temperature/brittleness test temperature
    Tests vulcanized rubber & other vulcanized material

Rubber low temperature brittleness tester has applications in scientific research testing, quality analysis, inspection units to measure highest temperature of vulcanized rubber & other materials.

{"Temperature range":"-60\u00b0C to 0\u00b0C","Temperature accuracy":"\u00b1 0.5\u00b0C","Measuring range":"","Accuracy":"","Load":"","Counter":"","Impact speed":"2 m\/s \u00b1 0.2 m\/s","Temperature fluctuation":"<\u00b1 0.5\u00b0C","Distance between center of impact or bottom of gripper":"11 \u00b1 0.5 mm","Outer dimension":"720\u00d7700\u00d71380 mm","Cold well volume":"700 ml","Dimension":"","Power":"1100 W","Net weight":"180 kg"}
Analogue display to observe temperature value
-60°C to 0°C low temperature range
Indications for highest temperature/brittleness test temperature
Tests vulcanized rubber & other vulcanized material
Rubber low temperature brittleness tester has applications in scientific research testing, quality analysis, inspection units to measure highest temperature of vulcanized rubber & other materials.


Related Products of Rubber Testing Instruments

Rubber-weiss plasticity testing machine TRWM-A10

Rubber-weiss plasticity testing machine TRWM-A10

Temperature range : RT 50° to 300°

Temperature accuracy : ± 1°

Measuring range : 0.01 to 25 mm

Three roll mill machine TRMM-A10

Three roll mill machine TRMM-A10

Mixed capacity : 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg

Temperature range : RT to 300°C

Temperature control system : PID control

Mooney viscometer TMV-A10
Mooney viscometer TMV-A10

Control temperature range : Normal temperature to 200°C

Temperature display resolution : 0.01°C

Temperature control accuracy : ± 0.3°

No rotor rheometer TNRR-A10
No rotor rheometer TNRR-A10

Temperature tester : Room temperature to 200°C

Temperature display resolution : 0.1°C

Temperature control accuracy : ≤ ± 0.3°C

DIN abrasion tester TDAT-A10

DIN abrasion tester TDAT-A10

Test arm weight : 2.5 N

Additional Loads : 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,

Idler : 150 mm

Rubber Low Temperature Brittleness Tester TRBT-A11

Rubber Low Temperature Brittleness Tester TRBT-A11

Temperature control range : Room temperature to -70 ℃ (room temperature ≤ 25 ℃)

Temperature accuracy : ± 0.3 ℃

Impact speed : 0℃ to -30℃ around 2.5 ℃/min
-30℃ to -40℃ around 2.5 ℃/min
-40℃ to -70℃ around 2.0 ℃/min

Plastic Testing Instruments

Aging Oven TAO-A10

The maximum temperature 300°C
Temperature fluctuation Within ± 0.5°C
Temperature uniformity Within ± 1°C

Vacuum Leak Tester TVLT-A10

Vacuum degree 0 to 90 KPa
Accuracy 1 % FS
Resolution 0.1 KPa

Paper Testing Instruments

Whiteness meter TP-A11
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source
Whiteness and chromaticity tester TP-A10
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min

Other Testing Instruments

Benchtop gloss meter TBGM-A10

Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU

Soil Testing Instruments

Soil nutrient tester TSNA-A11

Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Soil nutrient tester TSNA-A10
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %

NDT Testing Instruments

Rockwell hardness meter TRHM-A11
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S

Rockwell hardness meter TRHM-A10

Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S