Soil Salinity tester TSST-A10 with handheld design is suitable for accurate measurement of both soil temperature & soil salinity. Equipped with easy to use key buttons, user friendly controls, durable design, it is perfect for the field operations across agriculture, gardening, and construction industry.
Buy Now View CatalogSalinity Measurement range | 0.00 to 19.99 ms/cm |
Measuring accuracy | EC ± 2% full scale |
Temperature Measurement range | -5 to 50°C |
Temperature accuracy | ± 0.5°C |
Temperature compensation | 0 to 50°C |
Resolution | 0.01 ms/cm |
Memory storage | Stores 12000 groups data storage |
Working temperature | 0 to 50 °C |
Gross weight | 15 kg |
Power | 5 pcs AA batteries, power adapter |
Used to measure soil salinity of fertile, regular, dry soil etc. in agriculture, farming industry and across scientific research labs, geology.
Measurement range : 0 to 60 %
Resolution : 0.1
Accuracy : ± 5 % n (non-saturation condition)
Maximum load : 100 kg ( kg and N can be switched automatically)
Resolution : 0.01 g
Accuracy : ± 0.5 %
Measuring range : 0.001 to 9999
Stability : A (absorbency of light) <0.003 within 3 mins
Linearity error : <3.0 %
Measurement range : 0 to 90 %
Resolution : 0.1 or 0.01
Accuracy : ± 5 % n (non-saturation condition)
Measurement range : 0 to 80 %
Resolution : 0.1
Accuracy : ± 2 % n (non-saturation condition)
Measuring range : 0.001 to 9999
Stability : A (absorbency of light) <0.003 within 3 mins
Linearity error : <3.0 %
Maximum load : 100 kg ( kg and N can be switched automatically)
Resolution : 0.01 g
Accuracy : ± 0.5 %
Measuring range : 0 to 100 kPa
Resolution : 0.01 kPa
Accuracy : ± 1 kPa
Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
Temperature range | RT to 300°C |
Temperature control system | PID control |
Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
Temperature accuracy | ± 0.3 ℃ |
Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 1 to 30 S |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 0 to 30 S |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
Stability | ≤ 0.1 within 30 min |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
Light source | D65 as illuminating source |
Test angle | 60° |
Gloss aperture | 2 × 3 mm |
Measurement range | 0 to 1000 GU |
Vacuum degree | 0 to 90 KPa |
Accuracy | 1 % FS |
Resolution | 0.1 KPa |
The maximum temperature | 300°C |
Temperature fluctuation | Within ± 0.5°C |
Temperature uniformity | Within ± 1°C |
Talk to us?