Digital Brinell Hardness Tester TDBH-A10 with advanced design tests the hardness of the material on Brinell scale. The traditional method of using heavy weights for Brinell testing is replaced by using photo/pressure sensor with more accurate results. It is used to determine the Brinell hardness of cast-iron, ferrous & non-ferrous metal, soft alloys & other nonmetallic materials. The digital display controls parameters like dwell time, test force etc.
Buy Now View Catalog| Test force | 612.5 N, 980 N, 1225 N |
| Brinell hardness test | 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N |
| Hardness measuring area | 8 to 650 HBW (hard metals steel ball) |
| Hardness value symbol | |
| Error range in display | |
| Hardness indication | Digital display |
| Hardness value range in Measure | |
| Ball indenter | 2.5, 5, 10 mm |
| Magnification of Microscope | 20x |
| Loading control | Automatic |
| Standrad hardness block | HBW/3000/10 with 150 to 250, HBW/1000/10 with 75 to 125, HBW/187.5/2.5 with 150 to 250 |
| Pressure holding time | |
| Min. measurable unit | |
| Maximum height of specimen | 220 mm |
| Maximum depth of specimen | 135 mm |
| Max. height of sample | |
| Distance from intenders center to outer wall | |
| Illumination light | LED |
| Main body weight | 123 kg |
| Dimension of machine | 236 × 550 × 753 mm |
| Power supply | AC 220 V, 50 Hz |
Digital Brinell hardness tester has applications in inspection, research, metal & other non-destructive material industry.
Test force : 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
Hardness value symbol : HV1, HV5, HV10, HV20, HV30, HV250
Error range in display : ± 3.0 %, ± 2.0 %
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Total test force dwell time : 1 to 30 S
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Total test force dwell time : 0 to 30 S
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Brinell hardness test : 306, 613, 1839 N
Frequency (continually adjustable) : 10 Hz to1280 Hz + 0.01 %
Amplitude acceleration ( at 30m/s2 pk ) : 40 Hz to 320 Hz + 0.3 dB + 1 digit
Amplitude velocity ( at 25mm / sec pk ) : 40 Hz to 320 Hz + 0.5dB +1 digit
| Test angle | 60° |
| Gloss aperture | 2 × 3 mm |
| Measurement range | 0 to 1000 GU |
| The maximum temperature | 300°C |
| Temperature fluctuation | Within ± 0.5°C |
| Temperature uniformity | Within ± 1°C |
| Vacuum degree | 0 to 90 KPa |
| Accuracy | 1 % FS |
| Resolution | 0.1 KPa |
| Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
| System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
| Light source | D65 as illuminating source |
| Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
| Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
| Stability | ≤ 0.1 within 30 min |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
| Temperature range | RT to 300°C |
| Temperature control system | PID control |
| Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
| Temperature accuracy | ± 0.3 ℃ |
| Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |