Lasting adhesive tester TLAT-A10 comes with test plate having adhesive specimen hanged virtually on the stand & its bottom is attached with standard weight. The lasting adhesive property could be obtained by measuring the displacement of specimen on vertical test plate or the time to failure at such load. Equipped with 3 or 6 stations to perform group tests as well as to conduct individual test at each station. The auto timing & locking functions provides highly accurate test results. The standard test plates & weights ensures the accuracy of the test results data.
Buy Now View CatalogStandard roller | 2000 ± 50 g |
Testing stations | 3 |
Dimension (L*W*H) tester | 320×210×550 mm (3 stations) |
Weight for stations | 10 kg (3 stations) |
Weight of the plates | 1000 ± 3 g ( with triangle hook) |
Test plate (L*W*H) | 125×50×1.5 mm |
Timing range | 0 to 99 h 59 min 59 S |
Power | AC 220 V, 50 Hz |
Lasting adhesive tester has applications in plastic & packaging industry, stationary making industry.
Measuring range : 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
Measuring rate : 0.001 S
Temperature range : 50 to 400°C
Temperature range : 10 to 35°C
Maximum falling height : 2000 mm
Resolution of displacement : 1 mm
Measuring range : 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
Measuring rate : 0.001 S
Temperature range : 50 to 400°C
Impact Speed & Energy (charpy) : 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
Impact energy (Izod) : 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
Resolution of impact energy : 0.001 J
The maximum temperature : 300°C
Temperature fluctuation : Within ± 0.5°C
Temperature uniformity : Within ± 1°C
Inclined adjustable angle : 0 to 40°
Panel width : 120 mm
Test area width : 80 mm
Resolution : 0.1 % O2
Measuring range : 0 to 100 % O2
Precision : ± 0.4 % O2
Operating temperature : Ambient temperature to 300°C
Heating rate : 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
Maximum temp. error with heating speed : ± 5°C under 50°C/ h, ± 1°C under 120°C/ h
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
Stability | ≤ 0.1 within 30 min |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
Light source | D65 as illuminating source |
Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
Temperature accuracy | ± 0.3 ℃ |
Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
Temperature range | RT to 300°C |
Temperature control system | PID control |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 1 to 30 S |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 0 to 30 S |
Test angle | 60° |
Gloss aperture | 2 × 3 mm |
Measurement range | 0 to 1000 GU |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |