A PHP Error was encountered

Severity: Warning

Message: fopen(/var/cpanel/php/sessions/ea-php74/ci_sessionbcd7bd34ad3dde8344533020571744e5b76ca8f6): failed to open stream: Disk quota exceeded

Filename: drivers/Session_files_driver.php

Line Number: 176

Backtrace:

File: /home/danish786/public_html/labtron.uk/application/controllers/Website.php
Line: 8
Function: __construct

File: /home/danish786/public_html/labtron.uk/index.php
Line: 318
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/cpanel/php/sessions/ea-php74)

Filename: Session/Session.php

Line Number: 143

Backtrace:

File: /home/danish786/public_html/labtron.uk/application/controllers/Website.php
Line: 8
Function: __construct

File: /home/danish786/public_html/labtron.uk/index.php
Line: 318
Function: require_once

Heat sealer THS-A10 | labtron.uk

Heat sealer THS-A10

Heat sealer THS-A10 works on heat press seal method, before start of the test, user needs to preset the heat seal temperature, pressure and dwell time values so as to finish the entire sealing process automatically just after pressing the start button. Equipped with digital P.I.D. temperature control technology ensures the preset temperature to be reached rapidly without any fluctuation. The specimen is placed in between the upper & lower jaws with independent temperature control of upper & lower jaws.

Buy Now View Catalog
Seal temperature Room temperature -250°C
Control accuracy ± 0.2°C
Dwell time 0.1 S to 999.9 S
Dwell pressure 0.05 to 0.7 MPa
Heating mode Single and double heating surface
Dimension (L*B*H) 400×280×380 mm
Net weight 30 kg
Power supply AC 220V/ 50Hz
  • Specially designed heat sealing jaws
    Digital PID controlled system
    Manual or pedal switch
    Anti-scald design
    Large size touch screen for smooth operations
    Independent temperature control for upper & lower jaws

Heat sealer is used in plastic film material packaging, soft packaging laminated film & others to heat seal material using temperature, heat, pressure.

{"Seal temperature":"Room temperature -250\u00b0C","Control accuracy":"\u00b1 0.2\u00b0C","Dwell time":"0.1 S to 999.9 S","Dwell pressure":"0.05 to 0.7 MPa","Heating mode":"Single and double heating surface","Dimension (L*B*H)":"400\u00d7280\u00d7380 mm","Net weight":"30 kg","Power supply":"AC 220V\/ 50Hz"}
Specially designed heat sealing jaws
Digital PID controlled system
Manual or pedal switch
Anti-scald design
Large size touch screen for smooth operations
Independent temperature control for upper & lower jaws
Heat sealer is used in plastic film material packaging, soft packaging laminated film & others to heat seal material using temperature, heat, pressure.


Related Products of Plastic Testing Instruments

Oxygen Index Tester TOIT-A10

Oxygen Index Tester TOIT-A10

Resolution : 0.1 % O2

Measuring range : 0 to 100 % O2

Precision : ± 0.4 % O2

Charpy/ Izod Impact Tester TCI-A10

Charpy/ Izod Impact Tester TCI-A10

Impact Speed & Energy (charpy) : 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J

Impact energy (Izod) : 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J

Resolution of impact energy : 0.001 J

Vicat softening temperature & HDT machine TVHT-A10
Vicat softening temperature & HDT machine TVHT-A10

Operating temperature : Ambient temperature to 300°C

Heating rate : 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)

Maximum temp. error with heating speed : ± 5°C under 50°C/ h, ± 1°C under 120°C/ h

Primary adhesive tester TPAT-A10
Primary adhesive tester TPAT-A10

Inclined adjustable angle : 0 to 40°

Panel width : 120 mm

Test area width : 80 mm

Lasting adhesive tester TLAT-A10

Lasting adhesive tester TLAT-A10

Standard roller : 2000 ± 50 g

Testing stations : 3

Dimension (L*W*H) tester : 320×210×550 mm (3 stations)

Melt flow Indexer TMFI-A11

Melt flow Indexer TMFI-A11

Measuring range : 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)

Measuring rate : 0.001 S

Temperature range : 50 to 400°C

Vacuum Leak Tester TVLT-A10
Vacuum Leak Tester TVLT-A10

Vacuum degree : 0 to 90 KPa

Accuracy : 1 % FS

Resolution : 0.1 KPa

Melt flow Indexer TMFI-A10
Melt flow Indexer TMFI-A10

Measuring range : 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)

Measuring rate : 0.001 S

Temperature range : 50 to 400°C

Other Testing Instruments

Benchtop gloss meter TBGM-A10

Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU

NDT Testing Instruments

Rockwell hardness meter TRHM-A11

Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S
Rockwell hardness meter TRHM-A10
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S

Soil Testing Instruments

Soil nutrient tester TSNA-A10
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %

Soil nutrient tester TSNA-A11

Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %

Rubber Testing Instruments

Three roll mill machine TRMM-A10

Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Rubber Low Temperature Brittleness Tester TRBT-A11
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min
-30℃ to -40℃ around 2.5 ℃/min
-40℃ to -70℃ around 2.0 ℃/min

Paper Testing Instruments

Whiteness meter TP-A11
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source

Whiteness and chromaticity tester TP-A10

Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min