Paper and cardboard thickness meter TP-E21 measures thickness of paper, corrugated papers using contact measurement method. The Analogue (pointer type) type gauge display is mounted at top with a false weight so as to develop a uniform, reproducible constant pressure on the anvil through the foot. It finds applications in paper, printing, and packaging industry.
Buy Now View CatalogSample size (L*B) | |
Rub pressure | |
Friction speed | |
Friction area (L*B) | |
No. of friction | |
Measuring range | 0 to 20 mm |
Division value | |
Accuracy | 0.01 mm |
Gauge | Analogue gauge display |
Contact pressure (to create false weight) | 20 ± 0.5 kPa |
Contact diameter | 35.7 ± 0.5 mm |
Error of depth parallelism | 0.03 mm |
Testing speed | |
Test range | |
Indicating Error | ± 0.0025 mm or ± 0.5 % |
Indication variability | ≤ 0.0025 mm or ≤ 0.5 % |
Pressing depth of the measuring head | |
Parallelism error between two brims of the specimen stages | |
Slit width of the specimen stage | |
Testing length | |
Sample size | |
Bend angle | |
Sample width | |
Sample maximum length | |
Parallelism | |
Dimension | 233×160×120 mm |
Weight | 5.5 kg |
Power supply |
Thickness tester is used to measure thickness of paper, corrugated paper, cardboard & other sheets widely used in paper testing, printing, packaging industry.
Sample (size) length : 90 to 200 mm
Sample width : 15 mm, 25 mm, 50mm
Measuring range : 0 to 30, 0 to 100 N,0 to 300 N
Measuring range : 0 to 1000 mN
Resolution : 0.1 mN
Indication error : ± 1 %
Measuring range : 0.1 to 10 kN
Indication error : < ± 1%
Platen Size : 500×500 mm (customized)
Sample width : 15 mm
Sample maximum length : 300 mm
Parallelism : ≤ 0.1 mm
Measuring range : 0 to 1000 ml/min
Test area : 10 ± 0.02 cm2
Area differential pressure : 1 ± 0.01 kPa
Sample size (L*B) : 230×50 mm (can join short samples together)
Rub pressure : 20 ± 0.2 N
Friction speed : 43 times / min
Capacity : 10 -16000 mN
Resolution : 0.1 mN
Tearing arm : 104 ± 1 mm
Measuring scope : 0 to 99999 s
Folding angle : 135° ± 2°
Tensile scope : 4.9 to 14.7 N
The maximum temperature | 300°C |
Temperature fluctuation | Within ± 0.5°C |
Temperature uniformity | Within ± 1°C |
Vacuum degree | 0 to 90 KPa |
Accuracy | 1 % FS |
Resolution | 0.1 KPa |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 0 to 30 S |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 1 to 30 S |
Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
Temperature range | RT to 300°C |
Temperature control system | PID control |
Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
Temperature accuracy | ± 0.3 ℃ |
Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Test angle | 60° |
Gloss aperture | 2 × 3 mm |
Measurement range | 0 to 1000 GU |