Crush tester TP-L10 is adopted with advanced parts, microprocessor controlled system and multifunctional design to test, translate, adjust, display, remember, and print the test data. User can conduct any test of choice like TCT, FCT, ECT, and PAT for paper and cardboard material by selecting additional, corresponding accessories.
Buy Now View Catalog| Measurement range | 5 to 500 N, 50 to 3000 N |
| Measuring scope | |
| Folding angle | |
| Tensile scope | |
| Folding head suture size | |
| Folding radius | |
| Resolution | 1 N |
| Accuracy | ± 1 % |
| Variability | ≤ 1 % |
| Speed | 12.5 ± 2.5 mm/min |
| Vacuum system volume (ml) | |
| Contact pressure | |
| Vacuum scope | |
| Air volume (50.66 kPa down to 48.00 kPa) | |
| Maximum distance | 78 mm |
| Compression speed | |
| Clamp pressure | |
| Diameter of upper clamp | |
| Diameter of lower clamp | |
| Pneumatic pressure | |
| Film resistance | |
| Dimension | 450×400×500 mm |
| Net weight | 75 kg |
| Power supply | AC220 V ± 10 % , 50 Hz |
The crush tester is used to test crush strength of paper & paperboard using different auxiliary appliances across paper & printing, packaging industry.
Metal Cylinder inner area : (100 ± 0.2) cm2
Metal Cylinder height : 50 mm
Metal roller width : (200 ± 0..5) mm
Sample (size) length : 0 to 200 mm adjustable
Sample width : 15 mm
Measuring range : 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Measurement range : 0 to 5600 kPa
Accuracy : ± 0.5 % F.S.
Compression speed : 170 ± 15 ml/min
Measuring range : 0.1 to 10 kN
Indication error : < ± 1%
Platen Size : 500×500 mm (customized)
Measuring range : 0 to 1000 ml/min
Test area : 10 ± 0.02 cm2
Area differential pressure : 1 ± 0.01 kPa
Sample diameter : 125 mm
Sample error : ± 0.2 mm
Sample Thickness : 0.1 to 1.0 mm
Measuring scope : ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy : ±0.1 s within 300 s
Vacuum system volume (ml) : Bigger volume: 380 ± 1
Smaller volume: 38 ± 1
Measuring scope : 0 to 99999 s
Folding angle : 135° ± 2°
Tensile scope : 4.9 to 14.7 N
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 1 to 30 S |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 0 to 30 S |
| The maximum temperature | 300°C |
| Temperature fluctuation | Within ± 0.5°C |
| Temperature uniformity | Within ± 1°C |
| Vacuum degree | 0 to 90 KPa |
| Accuracy | 1 % FS |
| Resolution | 0.1 KPa |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Test angle | 60° |
| Gloss aperture | 2 × 3 mm |
| Measurement range | 0 to 1000 GU |
| Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
| Temperature range | RT to 300°C |
| Temperature control system | PID control |
| Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
| Temperature accuracy | ± 0.3 ℃ |
| Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |