Folding endurance tester TP-M10 is used to measure the folding endurance of paper, cardboard and other paper like sheet, material. The folding clamp can be positioned automatically. The microprocessor controlled technology, complete functions, stable performance, easy to use parameters are the advantages of this instrument.
Buy Now View Catalog| Measurement range | |
| Measuring scope | 0 to 99999 s |
| Folding angle | 135° ± 2° |
| Tensile scope | 4.9 to 14.7 N |
| Folding head suture size | 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm |
| Folding radius | 0.38 ± 0.02 mm |
| Resolution | |
| Accuracy | |
| Variability | |
| Speed | |
| Vacuum system volume (ml) | |
| Contact pressure | |
| Vacuum scope | |
| Air volume (50.66 kPa down to 48.00 kPa) | |
| Maximum distance | |
| Compression speed | |
| Clamp pressure | |
| Diameter of upper clamp | |
| Diameter of lower clamp | |
| Pneumatic pressure | |
| Film resistance | |
| Dimension | 320×320×450 mm |
| Net weight | 35 kg |
| Power supply | AC220 V ± 10 % , 50 Hz |
Folding endurance tester has applications in paper industry, cardboard, packaging industry.
Measurement range : 0 to 200 mm
Specimen size : 15×250 mm
Division value : 1 mm
Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable)
Sample width : 15 mm
Measuring range : 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Measurement range : 0 to 1600 kPa
Accuracy : ± 0.5 % F.S.
Compression speed : 95 ± 5 ml/min
Sample (size) length : 38×70 mm
Measuring range : (1-500) mN.m (divided into 7 small ranges)
Indication error : 0.02
Measuring range : 0 to 1000 ml/min
Test area : 10 ± 0.02 cm2
Area differential pressure : 1 ± 0.01 kPa
Measuring range : 0.1 to 10 kN
Indication error : < ± 1%
Platen Size : 500×500 mm (customized)
Measuring range : 0 to 4 mm
Accuracy : 0.01 or 0.001 mm
Gauge : Analogue gauge display
Capacity : A: 20 to 500 J/m2 B: 500 to 1000 J/m2
Impact angle : 90°
Unit : Lb-ft/in2 J/m2
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 1 to 30 S |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 0 to 30 S |
| The maximum temperature | 300°C |
| Temperature fluctuation | Within ± 0.5°C |
| Temperature uniformity | Within ± 1°C |
| Vacuum degree | 0 to 90 KPa |
| Accuracy | 1 % FS |
| Resolution | 0.1 KPa |
| Test angle | 60° |
| Gloss aperture | 2 × 3 mm |
| Measurement range | 0 to 1000 GU |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
| Temperature range | RT to 300°C |
| Temperature control system | PID control |
| Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
| Temperature accuracy | ± 0.3 ℃ |
| Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
Talk to us?