Electronic bending stiffness tester TP-E10 comes with microprocessor controlled system, highly advanced motor, low noise operations determines the bending stiffness/ rigidity of paper, paperboard, and plastic films. Stiffness tester is equipped with pneumatic clamps to hold the sample properly and eliminate the errors. It can determine the bending force (mN), bending stiffness torque (mNm) values of paper and cardboard, plastic films.
Buy Now View Catalog| Sample size (L*B) | |
| Rub pressure | |
| Friction speed | |
| Friction area (L*B) | |
| No. of friction | |
| Measuring range | |
| Division value | |
| Accuracy | |
| Gauge | |
| Contact pressure (to create false weight) | |
| Contact diameter | |
| Error of depth parallelism | |
| Testing speed | 200° ± 20° / min |
| Test range | 1 to 10000 mN |
| Indicating Error | ± 1 % |
| Indication variability | |
| Pressing depth of the measuring head | |
| Parallelism error between two brims of the specimen stages | |
| Slit width of the specimen stage | |
| Testing length | 5, 10, 15, 20, 25, 50 mm |
| Sample size | Width 38 ± 0.2 mm, length 70 mm |
| Bend angle | 1 to 90° |
| Sample width | |
| Sample maximum length | |
| Parallelism | |
| Dimension | 200×230×350 mm |
| Weight | 15 kg |
| Power supply | AC220 V ± 10 % , 50 Hz |
Electronic bending stiffness tester is used to test the bending stiffness of paper and cardboard, plastic films
Sample size (L*B) : 230×50 mm (can join short samples together)
Rub pressure : 20 ± 0.2 N
Friction speed : 43 times / min
Measuring scope : ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy : ±0.1 s within 300 s
Vacuum system volume (ml) : Bigger volume: 380 ± 1
Smaller volume: 38 ± 1
Capacity : A: 20 to 500 J/m2 B: 500 to 1000 J/m2
Impact angle : 90°
Unit : Lb-ft/in2 J/m2
Measuring scope : 0 to 99999 s
Folding angle : 135° ± 2°
Tensile scope : 4.9 to 14.7 N
Metal Cylinder inner area : (100 ± 0.2) cm2
Metal Cylinder height : 50 mm
Metal roller width : (200 ± 0..5) mm
Measurement range : 0 to 200 mm
Specimen size : 15×250 mm
Division value : 1 mm
Measurement range : 0 to 1600 kPa
Accuracy : ± 0.5 % F.S.
Compression speed : 95 ± 5 ml/min
Measuring range : 0 to 1000 mN
Resolution : 0.1 mN
Indication error : ± 1 %
| The maximum temperature | 300°C |
| Temperature fluctuation | Within ± 0.5°C |
| Temperature uniformity | Within ± 1°C |
| Vacuum degree | 0 to 90 KPa |
| Accuracy | 1 % FS |
| Resolution | 0.1 KPa |
| Test angle | 60° |
| Gloss aperture | 2 × 3 mm |
| Measurement range | 0 to 1000 GU |
| Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
| Temperature accuracy | ± 0.3 ℃ |
| Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
| Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
| Temperature range | RT to 300°C |
| Temperature control system | PID control |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 1 to 30 S |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 0 to 30 S |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |