Softness tester TP-H10 is adopted with microprocessor controlled technology and liquid crystal display to view and observe test parameters and result values. It can calculate and print test data. Its compact and sleek design, easy operations makes it user friendly. It is used to measure softness of paper, tissue paper, sheets, fabric etc.
Buy Now View Catalog| Sample size (L*B) | |
| Rub pressure | |
| Friction speed | |
| Friction area (L*B) | |
| No. of friction | |
| Measuring range | 10 to 1000 mN |
| Division value | 1 mN |
| Accuracy | ± 1% |
| Gauge | |
| Contact pressure (to create false weight) | |
| Contact diameter | |
| Error of depth parallelism | |
| Testing speed | |
| Test range | |
| Indicating Error | ≤ 0.5 |
| Indication variability | |
| Pressing depth of the measuring head | 8 + 0.5 mm |
| Parallelism error between two brims of the specimen stages | ≤ 0.05 mm |
| Slit width of the specimen stage | 5 mm, 6.35 mm, 10 mm, 20 mm |
| Testing length | |
| Sample size | |
| Bend angle | |
| Sample width | |
| Sample maximum length | |
| Parallelism | |
| Dimension | 570×410×200 mm |
| Weight | 33 kg |
| Power supply | AC220 V ± 10 % , 50 Hz |
Softness tester can measure softness of materials such as toilet paper of all grades, tobacco sheet, fiber fabric and so on.
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode : Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability : ≤ 0.1 within 30 min
Measuring scope : ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy : ±0.1 s within 300 s
Vacuum system volume (ml) : Bigger volume: 380 ± 1
Smaller volume: 38 ± 1
Measurement range : 0 to 1600 kPa
Accuracy : ± 0.5 % F.S.
Compression speed : 95 ± 5 ml/min
Measurement range : 0.01 to 10 N
Slider weight : 200 g
Slider size : 63×63 mm
Sample diameter : 125 mm
Sample error : ± 0.2 mm
Sample Thickness : 0.1 to 1.0 mm
Testing speed : 200° ± 20° / min
Test range : 1 to 10000 mN
Indicating Error : ± 1 %
Measurement range : 0 to 100° SR
Sealed testing speed : 100 ± 10 mm/s
Volume of distilled water : 1000 ± 5 ml
Capacity : 10 -16000 mN
Resolution : 0.1 mN
Tearing arm : 104 ± 1 mm
| Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
| Temperature accuracy | ± 0.3 ℃ |
| Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
| Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
| Temperature range | RT to 300°C |
| Temperature control system | PID control |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Test angle | 60° |
| Gloss aperture | 2 × 3 mm |
| Measurement range | 0 to 1000 GU |
| The maximum temperature | 300°C |
| Temperature fluctuation | Within ± 0.5°C |
| Temperature uniformity | Within ± 1°C |
| Vacuum degree | 0 to 90 KPa |
| Accuracy | 1 % FS |
| Resolution | 0.1 KPa |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 0 to 30 S |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 1 to 30 S |