Mullen burst tester TP-K10 is used to measure the bursting strength of paper submitted to increasing hydraulic pressure. Used in testing bursting strength of all types of papers in the 0 to 5600 kPa range depending on clamp pressure. It has mechanically & electrically integrated modern design, with compact structure & easy maintenance. The advantage of user-friendly operations, stable performance makes this tester an essential instrument for papermaking, packing, inspection and research.
Buy Now View Catalog| Measurement range | 0 to 5600 kPa |
| Measuring scope | |
| Folding angle | |
| Tensile scope | |
| Folding head suture size | |
| Folding radius | |
| Resolution | |
| Accuracy | ± 0.5 % F.S. |
| Variability | |
| Speed | |
| Vacuum system volume (ml) | |
| Contact pressure | |
| Vacuum scope | |
| Air volume (50.66 kPa down to 48.00 kPa) | |
| Maximum distance | |
| Compression speed | 170 ± 15 ml/min |
| Clamp pressure | ≥ 690 kPa |
| Diameter of upper clamp | 31.5 ± 0.05 mm |
| Diameter of lower clamp | 31.5 ± 0.05 mm |
| Pneumatic pressure | 0.45 to 0.6 MPa |
| Film resistance |
For bulge height = 10 mm, The pressure = 170 to 220 kPa For bulge height = 18 mm, The pressure = 250 to 350 kPa |
| Dimension | 480×420×600 mm |
| Net weight | 65 kg |
| Power supply | AC220 V ± 10 % , 50 Hz |
Mullen burst tester is used to measure bursting strength of paperboard, paper across paper industry, packaging industry, printing industry.
Sample (size) length : 90 to 200 mm
Sample width : 15 mm, 25 mm, 50mm
Measuring range : 0 to 30, 0 to 100 N,0 to 300 N
Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable)
Sample width : 15 mm
Measuring range : 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Measuring range : 0 to 4 mm
Accuracy : 0.01 or 0.001 mm
Gauge : Analogue gauge display
Sample (size) length : 0 to 200 mm adjustable
Sample width : 15 mm
Measuring range : 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
System : D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source : D65 as illuminating source
Measurement range : 0.01 to 10 N
Slider weight : 200 g
Slider size : 63×63 mm
Sample diameter : 125 mm
Sample error : ± 0.2 mm
Sample Thickness : 0.1 to 1.0 mm
| The maximum temperature | 300°C |
| Temperature fluctuation | Within ± 0.5°C |
| Temperature uniformity | Within ± 1°C |
| Vacuum degree | 0 to 90 KPa |
| Accuracy | 1 % FS |
| Resolution | 0.1 KPa |
| Test angle | 60° |
| Gloss aperture | 2 × 3 mm |
| Measurement range | 0 to 1000 GU |
| Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
| Temperature range | RT to 300°C |
| Temperature control system | PID control |
| Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
| Temperature accuracy | ± 0.3 ℃ |
| Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 1 to 30 S |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 0 to 30 S |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |