Coefficient of friction tester TP-D10 is used in testing the static & kinetic friction coefficient of plastic films and sheet. Tester is designed in accordance with ISO 8295 standard. It is supported by professional software to print single or group results, reports and curves automatically.
Buy Now View Catalog| Measurement range | 0.01 to 10 N |
| Slider weight | 200 g |
| Slider size | 63×63 mm |
| Testing accuracy | ± 2 % |
| Dimension of working plate | 170×225 mm |
| Speed of slider | 100 ± 1 0mm/min |
| Slider stroke | Max 100 mm (adjustable) |
| Specimen size | |
| Division value | |
| Number of specimen holders | |
| Metal Cylinder inner area | |
| Metal Cylinder height | |
| Metal roller width | |
| Metal roller weight | |
| Absorbency paper | |
| Absorbency speed | |
| Sealed testing speed | |
| Volume of distilled water | |
| Sample diameter | |
| Sample error | |
| Sample Thickness | |
| Draining time | |
| Residual water volume | |
| Hydraulic pressure | |
| Dimension | |
| Net Weight |
Coefficient of friction tester is used to test kinetic and static coefficient of friction samples, materials used in paper & cardboard industry.
Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable)
Sample width : 15 mm
Measuring range : 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Capacity : A: 20 to 500 J/m2 B: 500 to 1000 J/m2
Impact angle : 90°
Unit : Lb-ft/in2 J/m2
Measurement range : 0 to 200 mm
Specimen size : 15×250 mm
Division value : 1 mm
Measuring range : 0 to 4 mm
Accuracy : 0.01 or 0.001 mm
Gauge : Analogue gauge display
Sample diameter : 125 mm
Sample error : ± 0.2 mm
Sample Thickness : 0.1 to 1.0 mm
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode : Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability : ≤ 0.1 within 30 min
Measuring range : 0.1 to 10 kN
Indication error : < ± 1%
Platen Size : 500×500 mm (customized)
| Test angle | 60° |
| Gloss aperture | 2 × 3 mm |
| Measurement range | 0 to 1000 GU |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 0 to 30 S |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 1 to 30 S |
| The maximum temperature | 300°C |
| Temperature fluctuation | Within ± 0.5°C |
| Temperature uniformity | Within ± 1°C |
| Vacuum degree | 0 to 90 KPa |
| Accuracy | 1 % FS |
| Resolution | 0.1 KPa |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
| Temperature range | RT to 300°C |
| Temperature control system | PID control |
| Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
| Temperature accuracy | ± 0.3 ℃ |
| Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |