Paper air permeability tester TP-J10 is designed to measure the air permeability under specified conditions with time & unit pressure difference. It measures the average air flow through the unit area of the sheets. It is incorporated with standard ‘Paper porosity method’ used to test paper permeability. It is suitable for paper porosity with 1 x10 ˉ ² to 1 x10 ² µ m/ (Pa · S) range, and not suitable for large rough texture paper.
Buy Now View Catalog| Measuring range | 0 to 1000 ml/min |
| Capacity | |
| Resolution | |
| Indication error | |
| Tearing arm | |
| Tearing angle | |
| Chips distance | |
| Clamp- paper | |
| Resection length | |
| Tearing distance | |
| Frictional resistance | |
| Pyramid dimension | |
| Platen Size | |
| Operating stroke | |
| Compression speed | |
| Impact angle | |
| Unit | |
| Error | |
| Sample amount | |
| Speed adjustment range | |
| Track & force speed in stacking test | |
| Test area | 10 ± 0.02 cm2 |
| Area differential pressure | 1 ± 0.01 kPa |
| Inner diameter of grip ring | 35.68 ± 0.05 mm |
| Dimension | 410×300×1160 mm |
| Weight | About 15kg |
| Power supply |
Paper air permeability tester is used to measure air permeability of papers like cement sack paper, craft paper, cable paper, copy paper and industrial filter paper used in paper, packaging, craft industry.
Measurement range : 0 to 1600 kPa
Accuracy : ± 0.5 % F.S.
Compression speed : 95 ± 5 ml/min
Measuring range : 1 to 50 kN
Indication error : < ± 1%
Platen Size : 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
Metal Cylinder inner area : (100 ± 0.2) cm2
Metal Cylinder height : 50 mm
Metal roller width : (200 ± 0..5) mm
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
System : D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source : D65 as illuminating source
Measurement range : 0 to 100° SR
Sealed testing speed : 100 ± 10 mm/s
Volume of distilled water : 1000 ± 5 ml
Measurement range : 0.01 to 10 N
Slider weight : 200 g
Slider size : 63×63 mm
Measurement range : 0 to 5600 kPa
Accuracy : ± 0.5 % F.S.
Compression speed : 170 ± 15 ml/min
Sample (size) length : 38×70 mm
Measuring range : (1-500) mN.m (divided into 7 small ranges)
Indication error : 0.02
| Vacuum degree | 0 to 90 KPa |
| Accuracy | 1 % FS |
| Resolution | 0.1 KPa |
| The maximum temperature | 300°C |
| Temperature fluctuation | Within ± 0.5°C |
| Temperature uniformity | Within ± 1°C |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
| Temperature accuracy | ± 0.3 ℃ |
| Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
| Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
| Temperature range | RT to 300°C |
| Temperature control system | PID control |
| Test angle | 60° |
| Gloss aperture | 2 × 3 mm |
| Measurement range | 0 to 1000 GU |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 0 to 30 S |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 1 to 30 S |