Mullen burst tester TP-K11 is used to measure the bursting strength of paper submitted to increasing hydraulic pressure. Used in testing bursting strength of all types of papers in the 0 to 1600 kPa range depending on clamp pressure. It has mechanically & electrically integrated modern design, with compact structure & easy for maintenance. The advantage of user-friendly operations, stable performance makes this tester an essential instrument for papermaking, packing, inspection and research.
Buy Now View CatalogMeasurement range | 0 to 1600 kPa |
Measuring scope | |
Folding angle | |
Tensile scope | |
Folding head suture size | |
Folding radius | |
Resolution | |
Accuracy | ± 0.5 % F.S. |
Variability | |
Speed | |
Vacuum system volume (ml) | |
Contact pressure | |
Vacuum scope | |
Air volume (50.66 kPa down to 48.00 kPa) | |
Maximum distance | |
Compression speed | 95 ± 5 ml/min |
Clamp pressure | ≥ 430 kPa |
Diameter of upper clamp | 30.5 ± 0.05 mm |
Diameter of lower clamp | 33.1 ± 0.05 mm |
Pneumatic pressure | 0.3 to 0.5 MPa |
Film resistance | For bulge height = 9 mm, The pressure = 25 to 35 kPa |
Dimension | 480×420×600 mm |
Net weight | 65 kg |
Power supply | AC220 V ± 10 % , 50 Hz |
Mullen burst tester is used to measure bursting strength of paperboard, paper across paper industry, packaging industry, printing industry.
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode : Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability : ≤ 0.1 within 30 min
Measuring range : 0.1 to 10 kN
Indication error : < ± 1%
Platen Size : 500×500 mm (customized)
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
System : D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source : D65 as illuminating source
Measuring range : 0 to 1000 ml/min
Test area : 10 ± 0.02 cm2
Area differential pressure : 1 ± 0.01 kPa
Measuring scope : ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy : ±0.1 s within 300 s
Vacuum system volume (ml) : Bigger volume: 380 ± 1
Smaller volume: 38 ± 1
Sample (size) length : 90 to 200 mm
Sample width : 15 mm, 25 mm, 50mm
Measuring range : 0 to 30, 0 to 100 N,0 to 300 N
Metal Cylinder inner area : (100 ± 0.2) cm2
Metal Cylinder height : 50 mm
Metal roller width : (200 ± 0..5) mm
Sample (size) length : 38×70 mm
Measuring range : (1-500) mN.m (divided into 7 small ranges)
Indication error : 0.02
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 1 to 30 S |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 0 to 30 S |
Test angle | 60° |
Gloss aperture | 2 × 3 mm |
Measurement range | 0 to 1000 GU |
Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
Temperature accuracy | ± 0.3 ℃ |
Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
Temperature range | RT to 300°C |
Temperature control system | PID control |
The maximum temperature | 300°C |
Temperature fluctuation | Within ± 0.5°C |
Temperature uniformity | Within ± 1°C |
Vacuum degree | 0 to 90 KPa |
Accuracy | 1 % FS |
Resolution | 0.1 KPa |