Carton compression tester TP-I10 with 100 mm/min return speed level measures the compressive strength of carton box. The compressor tester, adopted with ARM chip, powerful data functioning system, advanced sensor and automatic tracking system for test operations. The test results are recorded automatically, the real-time display is used to view the test data and is transferrable to computer.
Buy Now View CatalogMeasuring range | 0.1 to 10 kN |
Capacity | |
Resolution | |
Indication error | < ± 1% |
Tearing arm | |
Tearing angle | |
Chips distance | |
Clamp- paper | |
Resection length | |
Tearing distance | |
Frictional resistance | |
Pyramid dimension | |
Platen Size | 500×500 mm (customized) |
Operating stroke | 500 mm (customized) |
Compression speed | 10 mm/ min |
Impact angle | |
Unit | |
Error | |
Sample amount | |
Speed adjustment range | 2 to 100 mm/ min |
Track & force speed in stacking test | 2 mm/ min |
Test area | |
Area differential pressure | |
Inner diameter of grip ring | |
Dimension | |
Weight | |
Power supply | AC220 V ± 10 % , 50 Hz |
Carton compression tester is used to determine compression strength & estimate stacking test of transport packages such as corrugated carton, paperboard box etc.
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
System : D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source : D65 as illuminating source
Measuring range : 0 to 4 mm
Accuracy : 0.01 or 0.001 mm
Gauge : Analogue gauge display
Capacity : 10 -16000 mN
Resolution : 0.1 mN
Tearing arm : 104 ± 1 mm
Measuring range : 0 to 20 mm
Accuracy : 0.01 mm
Gauge : Analogue gauge display
Measuring range : A (1 to 6) J indicating error ± 0.05 J
B (1 to 12) J indicating error ± 0.05 J
C (1 to 24) J indicating error ± 0.05 J
D (1 to 48) J indicating error ± 0.05 J
The indicating errors w.r.t measurement range of 20 to 80 %
Frictional resistance : <0.25 J
Pyramid dimension : Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable)
Sample width : 15 mm
Measuring range : 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Measurement range : 0 to 200 mm
Specimen size : 15×250 mm
Division value : 1 mm
Measuring scope : ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy : ±0.1 s within 300 s
Vacuum system volume (ml) : Bigger volume: 380 ± 1
Smaller volume: 38 ± 1
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 0 to 30 S |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 1 to 30 S |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Vacuum degree | 0 to 90 KPa |
Accuracy | 1 % FS |
Resolution | 0.1 KPa |
The maximum temperature | 300°C |
Temperature fluctuation | Within ± 0.5°C |
Temperature uniformity | Within ± 1°C |
Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
Temperature accuracy | ± 0.3 ℃ |
Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
Temperature range | RT to 300°C |
Temperature control system | PID control |
Test angle | 60° |
Gloss aperture | 2 × 3 mm |
Measurement range | 0 to 1000 GU |
Talk to us?