Internal Ply bond Tester TP-J11 is used to test the Z direction tensile internal (interlayer bonding) bonding strength of various paperboards. The instrument design is based on a falling pendulum which creates a high speed impact on a paper specimen. The test paper sample is impacted by certain angle and weight. The energy absorbed by the paper indicates the internal bonding strength of that paper.
Buy Now View Catalog| Measuring range | |
| Capacity | A: 20 to 500 J/m2 B: 500 to 1000 J/m2 |
| Resolution | |
| Indication error | |
| Tearing arm | |
| Tearing angle | |
| Chips distance | |
| Clamp- paper | |
| Resection length | |
| Tearing distance | |
| Frictional resistance | |
| Pyramid dimension | |
| Platen Size | |
| Operating stroke | |
| Compression speed | |
| Impact angle | 90° |
| Unit | Lb-ft/in2 J/m2 |
| Error | A: ± 1 J/m2 B: ± 2 J/m2 |
| Sample amount | 5 pcs |
| Speed adjustment range | |
| Track & force speed in stacking test | |
| Test area | |
| Area differential pressure | |
| Inner diameter of grip ring | |
| Dimension | 700×340×600 mm |
| Weight | 92 g |
| Power supply |
Internal ply bond tester is used in paper, corrugated paper & packaging industry.
Measuring range : 0 to 20 mm
Accuracy : 0.01 mm
Gauge : Analogue gauge display
Measuring range : A (1 to 6) J indicating error ± 0.05 J
B (1 to 12) J indicating error ± 0.05 J
C (1 to 24) J indicating error ± 0.05 J
D (1 to 48) J indicating error ± 0.05 J
The indicating errors w.r.t measurement range of 20 to 80 %
Frictional resistance : <0.25 J
Pyramid dimension : Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
Sample size (L*B) : 230×50 mm (can join short samples together)
Rub pressure : 20 ± 0.2 N
Friction speed : 43 times / min
Sample diameter : 125 mm
Sample error : ± 0.2 mm
Sample Thickness : 0.1 to 1.0 mm
Measuring range : 0 to 1000 mN
Resolution : 0.1 mN
Indication error : ± 1 %
Testing speed : 200° ± 20° / min
Test range : 1 to 10000 mN
Indicating Error : ± 1 %
Measurement range : 0 to 100° SR
Sealed testing speed : 100 ± 10 mm/s
Volume of distilled water : 1000 ± 5 ml
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Measuring range | 0.001 to 9999 |
| Stability | A (absorbency of light) <0.003 within 3 mins |
| Linearity error | <3.0 % |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 1 to 30 S |
| Preliminary test force | 98 N |
| Total test force | 588, 980, 1471 N |
| Total test force dwell time | 0 to 30 S |
| Test angle | 60° |
| Gloss aperture | 2 × 3 mm |
| Measurement range | 0 to 1000 GU |
| The maximum temperature | 300°C |
| Temperature fluctuation | Within ± 0.5°C |
| Temperature uniformity | Within ± 1°C |
| Vacuum degree | 0 to 90 KPa |
| Accuracy | 1 % FS |
| Resolution | 0.1 KPa |
| Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
| Temperature range | RT to 300°C |
| Temperature control system | PID control |
| Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
| Temperature accuracy | ± 0.3 ℃ |
| Impact speed | 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min |
Talk to us?